Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Overload release current setting252.0 - 630A
Position of connection for main current circuitFront side
Motor drive integratedNo
Rated voltage220 - 690V
Number of poles3
Degree of protection (IP)IP20
Rated permanent current Iu800A
Adjustment range short-term delayed short-circuit release- - -A
With switched-off indicatorNo
Type of control elementToggle
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
With integrated under voltage releaseNo
Motor drive optionalYes
Integrated earth fault protectionNo
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release630 - 6300A
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA107593R1 | XT6H 800 Ekip Dip LIG In=630 3p F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Overload release current setting

252.0 .. 630A

Position of connection for main current circuit

Front side

Motor drive integrated

Rated voltage

220 .. 690V

Number of poles

3

Degree of protection (IP)

IP20

Rated permanent current Iu

800A

Adjustment range short-term delayed short-circuit release

- .. -A

With switched-off indicator

Type of control element

Toggle

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

With integrated under voltage release

Motor drive optional

Integrated earth fault protection

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

630 .. 6300A

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.