Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Max. continuous voltage DC-V
Voltage protection level L-N-kV
Nominal voltage DC-V
Voltage protection level N-PE-kV
Max. PV-voltage-V
System configuration DCNo
System configuration TNYes
System configuration ITNo
System configuration TN-C-SNo
System configuration TN-CYes
System configuration otherNo
System configuration TTNo
Nominal discharge surge current (8/20)20kA
Number of conductors (without earthing)3
Mounting methodDIN rail (top hat rail) 35 mm
Max. discharge surge current (8/20)120kA
Max. continuous voltage AC350V
With remote signalling contactNo
Voltage protection level1.5kV
Max. conductor cross section solid (solid, stranded)25mm²
Integrated backup fuseNo
Construction size3 modular spacing
Short-circuit breaking capacity (Isccr)100kA
System configuration TN-SNo
Nominal voltage AC230V
Max. conductor cross section flexible (fine-strand)16mm²
Degree of protection (IP)IP20
Category type 2Yes
Signalling at the deviceOptic
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CTB803883R2400 | OVR T2 3L 40-350 P QS

Main Product Image

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Max. continuous voltage DC

-V

Voltage protection level L-N

-kV

Nominal voltage DC

-V

Voltage protection level N-PE

-kV

Max. PV-voltage

-V

System configuration DC

System configuration TN

System configuration IT

System configuration TN-C-S

System configuration TN-C

System configuration other

System configuration TT

Nominal discharge surge current (8/20)

20kA

Number of conductors (without earthing)

3

Mounting method

DIN rail (top hat rail) 35 mm

Max. discharge surge current (8/20)

120kA

Max. continuous voltage AC

350V

With remote signalling contact

Voltage protection level

1.5kV

Max. conductor cross section solid (solid, stranded)

25mm²

Integrated backup fuse

Construction size

3 modular spacing

Short-circuit breaking capacity (Isccr)

100kA

System configuration TN-S

Nominal voltage AC

230V

Max. conductor cross section flexible (fine-strand)

16mm²

Degree of protection (IP)

IP20

Category type 2

Signalling at the device

Optic

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.