Aleta.hr
Main Product Image

2CTB803982R1100 | OVR T2 1N 40-350 P QS

Code: 1895670

ManufacturerRAZNO
Catalog number2CTB803982R1100
Type
EAN code3660308519719

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Max. continuous voltage DC

-V

Nominal voltage DC

-V

Max. PV-voltage

-V

System configuration TT

Yes

System configuration DC

No

System configuration TN-C-S

Yes

System configuration TN-S

Yes

System configuration other

No

System configuration TN-C

No

Short-circuit breaking capacity (Isccr)

100kA

Max. continuous voltage AC

350V

System configuration TN

Yes

Voltage protection level

1.5kV

Number of conductors (without earthing)

2

Construction size

2 modular spacing

Max. discharge surge current (8/20)

80kA

Nominal voltage AC

230V

Mounting method

DIN rail (top hat rail) 35 mm

Nominal discharge surge current (8/20)

20kA

Max. conductor cross section solid (solid, stranded)

25mm²

Voltage protection level N-PE

1.4kV

With remote signalling contact

No

Max. conductor cross section flexible (fine-strand)

16mm²

Signalling at the device

Optic

Degree of protection (IP)

IP20

Voltage protection level L-N

1.25kV

Integrated backup fuse

No

Category type 2

Yes

System configuration IT

No


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CTB803982R1100 | OVR T2 1N 40-350 P QS

Main Product Image

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Max. continuous voltage DC

-V

Nominal voltage DC

-V

Max. PV-voltage

-V

System configuration TT

System configuration DC

System configuration TN-C-S

System configuration TN-S

System configuration other

System configuration TN-C

Short-circuit breaking capacity (Isccr)

100kA

Max. continuous voltage AC

350V

System configuration TN

Voltage protection level

1.5kV

Number of conductors (without earthing)

2

Construction size

2 modular spacing

Max. discharge surge current (8/20)

80kA

Nominal voltage AC

230V

Mounting method

DIN rail (top hat rail) 35 mm

Nominal discharge surge current (8/20)

20kA

Max. conductor cross section solid (solid, stranded)

25mm²

Voltage protection level N-PE

1.4kV

With remote signalling contact

Max. conductor cross section flexible (fine-strand)

16mm²

Signalling at the device

Optic

Degree of protection (IP)

IP20

Voltage protection level L-N

1.25kV

Integrated backup fuse

Category type 2

System configuration IT