Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- ABB
Technical specifications
Version as emergency stop installation
No
Version as maintenance-/service switch
Yes
Rated operating voltage
1500 - 1500V
Version as reversing switch
No
Version as safety switch
No
Version as main switch
Yes
Max. rated operation voltage Ue AC
-V
Rated operation power at AC-3, 400 V
-kW
Rated operation power at AC-23, 400 V
-kW
Rated permanent current Iu
250A
Switching power at 400 V
-kW
Rated permanent current at AC-23, 400 V
-A
Rated short-time withstand current lcw
-kA
Rated permanent current at AC-21, 400 V
-A
Number of switches
1
Conditioned rated short-circuit current Iq
-kA
Number of auxiliary contacts as normally open contact
0
Number of poles
2
Number of auxiliary contacts as normally closed contact
0
Motor drive optional
No
Voltage release optional
No
Device construction
Built-in device fixed built-in technique
Suitable for floor mounting
No
Suitable for front mounting 4-hole
Yes
Motor drive integrated
No
Suitable for front mounting centre
No
Suitable for distribution board installation
Yes
Type of control element
Other
Degree of protection (IP), front side
IP20
Number of auxiliary contacts as change-over contact
0
Suitable for intermediate mounting
No
Type of electrical connection of main circuit
Bolt connection
Interlockable
No
With pre-assembled cabling
No
Degree of protection (NEMA)
1
Width
161mm
Width in number of modular spacings
-
Depth
120mm
Height
165mm
From same serie
1SCA161995R1001 | OTDC250GV02S

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- ABB
Technical specifications
Version as emergency stop installation
Version as maintenance-/service switch
Rated operating voltage
1500 .. 1500V
Version as reversing switch
Version as safety switch
Version as main switch
Max. rated operation voltage Ue AC
-V
Rated operation power at AC-3, 400 V
-kW
Rated operation power at AC-23, 400 V
-kW
Rated permanent current Iu
250A
Switching power at 400 V
-kW
Rated permanent current at AC-23, 400 V
-A
Rated short-time withstand current lcw
-kA
Rated permanent current at AC-21, 400 V
-A
Number of switches
1
Conditioned rated short-circuit current Iq
-kA
Number of auxiliary contacts as normally open contact
0
Number of poles
2
Number of auxiliary contacts as normally closed contact
0
Motor drive optional
Voltage release optional
Device construction
Built-in device fixed built-in technique
Suitable for floor mounting
Suitable for front mounting 4-hole
Motor drive integrated
Suitable for front mounting centre
Suitable for distribution board installation
Type of control element
Other
Degree of protection (IP), front side
IP20
Number of auxiliary contacts as change-over contact
0
Suitable for intermediate mounting
Type of electrical connection of main circuit
Bolt connection
Interlockable
With pre-assembled cabling
Degree of protection (NEMA)
1
Width
161mm
Width in number of modular spacings
-
Depth
120mm
Height
165mm
From same serie