Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)2
Rated short-circuit breaking capacity according to EN 610096kA
Rated voltage240V
Rated current20A
Disconnection characteristicUndelayed
Rated insulation voltage Ui500V
Rated fault current0.01A
Surge current capacity2.5kA
Rated impulse withstand voltage Uimp4kV
Leakage current typeA
Voltage typeAC
Rated short-circuit breaking capacity according to IEC 60947-26kA
Current limiting class3
Power loss3W
Number of protected poles1
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Frequency50/60 Hz
Pollution degree2
Built-in depth70mm
Over voltage category3
Width in number of modular spacings1
With interlocking deviceNo
Concurrently switching neutral conductorYes
Release characteristicC
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired1 - 16mm²
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Connectable conductor cross section solid-core1 - 25mm²
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDB352501R0204 | DSN201E C20 A10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated voltage

240V

Rated current

20A

Disconnection characteristic

Undelayed

Rated insulation voltage Ui

500V

Rated fault current

0.01A

Surge current capacity

2.5kA

Rated impulse withstand voltage Uimp

4kV

Leakage current type

A

Voltage type

AC

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Current limiting class

3

Power loss

3W

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Frequency

50/60 Hz

Pollution degree

2

Built-in depth

70mm

Over voltage category

3

Width in number of modular spacings

1

With interlocking device

Concurrently switching neutral conductor

Release characteristic

C

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

1 .. 16mm²

Flush-mounted installation

Anti-nuisance tripping version

Connectable conductor cross section solid-core

1 .. 25mm²

Degree of protection (IP)

IP20

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.