Technical specifications

Degree of protection (IP)IP20
Voltage typeAC
Suitable for flush-mounted installationNo
Built-in depth69mm
Width in number of modular spacings3
Rated voltage400V
Rated current50A
Release characteristicC
Number of protected poles3
Over voltage category3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Number of poles (total)3
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V6kA
Additional equipment possibleNo
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Pollution degree2
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Flush-mounted installationNo
Connectable conductor cross section solid-core0.75 - 25mm²
Rated insulation voltage Ui440V
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 16mm²
Power loss9.75W
Ambient temperature during operating-25 - 55°C
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS213001R0504 | SH203-C50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

Built-in depth

69mm

Width in number of modular spacings

3

Rated voltage

400V

Rated current

50A

Release characteristic

C

Number of protected poles

3

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Number of poles (total)

3

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

6kA

Additional equipment possible

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Pollution degree

2

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Flush-mounted installation

Connectable conductor cross section solid-core

0.75 .. 25mm²

Rated insulation voltage Ui

440V

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 16mm²

Power loss

9.75W

Ambient temperature during operating

-25 .. 55°C

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.