Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)IP20
Voltage typeAC
Suitable for flush-mounted installationNo
Built-in depth69mm
Width in number of modular spacings3
Rated voltage400V
Rated current50A
Release characteristicB
Number of protected poles3
Over voltage category3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Number of poles (total)3
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V6kA
Additional equipment possibleNo
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Pollution degree2
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Ambient temperature during operating-25 - 55°C
Flush-mounted installationNo
Connectable conductor cross section solid-core0.75 - 25mm²
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 16mm²
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Power loss9.75W
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS213001R0505 | SH203-B50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

Built-in depth

69mm

Width in number of modular spacings

3

Rated voltage

400V

Rated current

50A

Release characteristic

B

Number of protected poles

3

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Number of poles (total)

3

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

6kA

Additional equipment possible

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Pollution degree

2

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Ambient temperature during operating

-25 .. 55°C

Flush-mounted installation

Connectable conductor cross section solid-core

0.75 .. 25mm²

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 16mm²

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Power loss

9.75W

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.