Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated current25A
Built-in depth68.9mm
Rated voltage230V
Voltage typeAC
Surge current capacity0.25kA
Rated insulation voltage Ui500V
Rated fault current0.03A
Leakage current typeAC
Release characteristicB
Current limiting class3
Over voltage category3
Degree of protection (IP)IP2X
Frequency50/60 Hz
Pollution degree2
Power loss3.8W
Width in number of modular spacings1
Rated short-circuit breaking capacity according to EN 608986kA
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core1 - 25mm²
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity according to IEC 60947-26kA
Number of protected poles1
With interlocking deviceYes
Connectable conductor cross section multi-wired1 - 16mm²
Ambient temperature during operating-25 - 55°C
Flush-mounted installationNo
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Anti-nuisance tripping versionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255051R1255 | DSE201 B25 AC30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated current

25A

Built-in depth

68.9mm

Rated voltage

230V

Voltage type

AC

Surge current capacity

0.25kA

Rated insulation voltage Ui

500V

Rated fault current

0.03A

Leakage current type

AC

Release characteristic

B

Current limiting class

3

Over voltage category

3

Degree of protection (IP)

IP2X

Frequency

50/60 Hz

Pollution degree

2

Power loss

3.8W

Width in number of modular spacings

1

Rated short-circuit breaking capacity according to EN 60898

6kA

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1 .. 25mm²

Suitable for flush-mounted installation

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Number of protected poles

1

With interlocking device

Connectable conductor cross section multi-wired

1 .. 16mm²

Ambient temperature during operating

-25 .. 55°C

Flush-mounted installation

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Anti-nuisance tripping version

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.