Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Signalling at the deviceNone
Mounting methodDIN rail (top hat rail) 35 mm
Nominal voltage DC1000V
Nominal voltage AC-V
Number of conductors (without earthing)2
Construction size3 modular spacing
Voltage protection level L-N-kV
With remote signalling contactNo
Voltage protection level3.8kV
Max. continuous voltage AC-V
Max. continuous voltage DC1000V
Category type 2Yes
Nominal discharge surge current (8/20)20kA
Max. conductor cross section solid (solid, stranded)35mm²
Integrated backup fuseNo
System configuration DCYes
Short-circuit breaking capacity (Isccr)11kA
Max. conductor cross section flexible (fine-strand)25mm²
Degree of protection (IP)IP20
System configuration ITNo
System configuration TN-CNo
Voltage protection level N-PE-kV
System configuration TN-SNo
Max. PV-voltage1000V
System configuration otherNo
Max. discharge surge current (8/20)40kA
System configuration TTNo
System configuration TNNo
System configuration TN-C-SNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CTB812052R1000 | OVR PV T1-T2 5-1000 C QS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Signalling at the device

None

Mounting method

DIN rail (top hat rail) 35 mm

Nominal voltage DC

1000V

Nominal voltage AC

-V

Number of conductors (without earthing)

2

Construction size

3 modular spacing

Voltage protection level L-N

-kV

With remote signalling contact

Voltage protection level

3.8kV

Max. continuous voltage AC

-V

Max. continuous voltage DC

1000V

Category type 2

Nominal discharge surge current (8/20)

20kA

Max. conductor cross section solid (solid, stranded)

35mm²

Integrated backup fuse

System configuration DC

Short-circuit breaking capacity (Isccr)

11kA

Max. conductor cross section flexible (fine-strand)

25mm²

Degree of protection (IP)

IP20

System configuration IT

System configuration TN-C

Voltage protection level N-PE

-kV

System configuration TN-S

Max. PV-voltage

1000V

System configuration other

Max. discharge surge current (8/20)

40kA

System configuration TT

System configuration TN

System configuration TN-C-S

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.