Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

With remote signalling contactNo
Max. continuous voltage AC-V
Mounting methodDIN rail (top hat rail) 35 mm
Construction size3 modular spacing
Number of conductors (without earthing)2
Voltage protection level5kV
Nominal discharge surge current (8/20)20kA
Nominal voltage DC1500V
Nominal voltage AC-V
Signalling at the deviceNone
Max. continuous voltage DC1500V
Degree of protection (IP)IP20
Category type 2Yes
Max. PV-voltage1500V
Voltage protection level L-N-kV
Voltage protection level N-PE-kV
Integrated backup fuseNo
System configuration TNNo
Max. conductor cross section solid (solid, stranded)35mm²
Max. conductor cross section flexible (fine-strand)25mm²
System configuration DCYes
System configuration TN-CNo
System configuration TN-SNo
System configuration ITNo
System configuration otherNo
Max. discharge surge current (8/20)40kA
System configuration TTNo
System configuration TN-C-SNo
Short-circuit breaking capacity (Isccr)11kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CTB812052R1500 | OVR PV T1-T2 5-1500 C QS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

With remote signalling contact

Max. continuous voltage AC

-V

Mounting method

DIN rail (top hat rail) 35 mm

Construction size

3 modular spacing

Number of conductors (without earthing)

2

Voltage protection level

5kV

Nominal discharge surge current (8/20)

20kA

Nominal voltage DC

1500V

Nominal voltage AC

-V

Signalling at the device

None

Max. continuous voltage DC

1500V

Degree of protection (IP)

IP20

Category type 2

Max. PV-voltage

1500V

Voltage protection level L-N

-kV

Voltage protection level N-PE

-kV

Integrated backup fuse

System configuration TN

Max. conductor cross section solid (solid, stranded)

35mm²

Max. conductor cross section flexible (fine-strand)

25mm²

System configuration DC

System configuration TN-C

System configuration TN-S

System configuration IT

System configuration other

Max. discharge surge current (8/20)

40kA

System configuration TT

System configuration TN-C-S

Short-circuit breaking capacity (Isccr)

11kA