Technical specifications

Mounting methodDIN rail (top hat rail) 35 mm
Max. continuous voltage AC1100V
Degree of protection (IP)IP20
Category type 2Yes
Nominal voltage DC1000V
Max. continuous voltage DC1000V
Nominal discharge surge current (8/20)20kA
Voltage protection level L-N-kV
Voltage protection level N-PE-kV
Max. PV-voltage1000V
Nominal voltage AC-V
Signalling at the deviceNone
Voltage protection level3.8kV
Construction size3 modular spacing
With remote signalling contactNo
Number of conductors (without earthing)2
System configuration ITNo
Max. conductor cross section flexible (fine-strand)25mm²
System configuration DCYes
Max. conductor cross section solid (solid, stranded)35mm²
System configuration TNNo
Integrated backup fuseNo
System configuration TN-SNo
Max. discharge surge current (8/20)40kA
System configuration TN-C-SNo
System configuration otherNo
System configuration TN-CNo
System configuration TTNo
Short-circuit breaking capacity (Isccr)11kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CTB812120R1000 | OVR PV T1-T2 12.5-1000 P QS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Mounting method

DIN rail (top hat rail) 35 mm

Max. continuous voltage AC

1100V

Degree of protection (IP)

IP20

Category type 2

Nominal voltage DC

1000V

Max. continuous voltage DC

1000V

Nominal discharge surge current (8/20)

20kA

Voltage protection level L-N

-kV

Voltage protection level N-PE

-kV

Max. PV-voltage

1000V

Nominal voltage AC

-V

Signalling at the device

None

Voltage protection level

3.8kV

Construction size

3 modular spacing

With remote signalling contact

Number of conductors (without earthing)

2

System configuration IT

Max. conductor cross section flexible (fine-strand)

25mm²

System configuration DC

Max. conductor cross section solid (solid, stranded)

35mm²

System configuration TN

Integrated backup fuse

System configuration TN-S

Max. discharge surge current (8/20)

40kA

System configuration TN-C-S

System configuration other

System configuration TN-C

System configuration TT

Short-circuit breaking capacity (Isccr)

11kA