Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class-
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of protected poles3
Built-in depth44mm
Rated impulse withstand voltage Uimp6kV
Rated current1A
Release characteristicK
Rated insulation voltage Ui690V
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Frequency50 - 60Hz
Over voltage category3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Connectable conductor cross section solid-core1 - 6mm²
Pollution degree3
Number of poles (total)3
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Connectable conductor cross section multi-wired1 - 6mm²
Width in number of modular spacings2.5
Explosion-proofNo
Degree of protection (IP)IP20
Ambient temperature during operating-20 - 60°C
Voltage typeAC
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

21104

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of protected poles

3

Built-in depth

44mm

Rated impulse withstand voltage Uimp

6kV

Rated current

1A

Release characteristic

K

Rated insulation voltage Ui

690V

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Frequency

50 .. 60Hz

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Connectable conductor cross section solid-core

1 .. 6mm²

Pollution degree

3

Number of poles (total)

3

Concurrently switching neutral conductor

Flush-mounted installation

Connectable conductor cross section multi-wired

1 .. 6mm²

Width in number of modular spacings

2.5

Explosion-proof

Degree of protection (IP)

IP20

Ambient temperature during operating

-20 .. 60°C

Voltage type

AC

Additional equipment possible

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.