Details
- •Low-voltage switchgear and control gear (automation)
- •Frequency converter =< 1 kV
- •1 KOM
- •SCHNEIDER
Technical specifications
ATV320U07M3C | Frek.pr. 0.75KW 200V 3PH-ATV320 Kompakt

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage switchgear and control gear (automation)
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Number of analogue outputs
1
Height
143mm
Number of analogue inputs
3
Number of digital outputs
1
Number of digital inputs
6
Width
72mm
With control element
Depth
138mm
Number of HW-interfaces RS-232
0
Number of HW-interfaces USB
0
Number of HW-interfaces RS-485
1
Supporting protocol for LON
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces serial TTY
0
Supporting protocol for SUCONET
With PC connection
Supporting protocol for ASI
Supporting protocol for PROFIBUS
With optical interface
Supporting protocol for TCP/IP
Degree of protection (IP)
IP20
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Number of HW-interfaces other
1
Supporting protocol for KNX
Number of HW-interfaces parallel
0
Supporting protocol for DeviceNet
Supporting protocol for SERCOS
Supporting protocol for INTERBUS
Supporting protocol for INTERBUS-Safety
Supporting protocol for other bus systems
Supporting protocol for CAN
Mains frequency
50/60 Hz
Number of phases input
3
Mains voltage
200 .. 240V
Number of phases output
3
4-quadrant operation possible
Number of interfaces PROFINET
0
Type of converter
U converter
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for BACnet
Integrated breaking resistance
Relative symmetric net voltage tolerance
10%
Max. output at quadratic load at rated output voltage
0.75kW
Nominal output current I2N
4.8A
Application in domestic- and commercial area permitted
Relative symmetric net frequency tolerance
5%
Supporting protocol for SafetyBUS p
Max. output at linear load at rated output voltage
0.75kW
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET CBA
Supporting protocol for PROFIsafe
Application in industrial area permitted
Max. output voltage
240V
Max. output frequency
599Hz
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFINET IO
Degree of protection (NEMA)
1