Aleta.hr
Main Product Image

ATV320U15S6C | Frek.pr. 1.5KW 600V 3PH-ATV320 Kompakt

Code: 1938640

ManufacturerSchneider
Catalog numberATV320U15S6C
Type
EAN code3606480966804

Details

  • Low-voltage switchgear and control gear (automation)
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of digital inputs6
Width105mm
With control elementYes
Supporting protocol for LONNo
Height142mm
Number of analogue outputs1
Depth158mm
Number of analogue inputs3
Number of HW-interfaces industrial Ethernet0
Number of digital outputs1
Supporting protocol for PROFIBUSYes
Number of HW-interfaces RS-4851
Supporting protocol for Data-HighwayNo
Number of HW-interfaces USB0
Number of HW-interfaces serial TTY0
Supporting protocol for TCP/IPYes
Number of HW-interfaces other1
Mains voltage525 - 600V
Number of HW-interfaces parallel0
With optical interfaceNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Supporting protocol for ASINo
Degree of protection (IP)IP20
Supporting protocol for SUCONETNo
Supporting protocol for CANYes
Supporting protocol for DeviceNetYes
Supporting protocol for other bus systemsYes
Number of HW-interfaces RS-2320
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for INTERBUSNo
Mains frequency50/60 Hz
With PC connectionYes
Number of HW-interfaces RS-4220
Degree of protection (NEMA)1
Number of phases input3
Number of phases output3
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for DeviceNet SafetyNo
Max. output voltage600V
Type of converterU converter
Supporting protocol for BACnetNo
Application in domestic- and commercial area permittedNo
Relative symmetric net voltage tolerance10%
Relative symmetric net frequency tolerance5%
Supporting protocol for AS-Interface Safety at WorkNo
Integrated breaking resistanceYes
Supporting protocol for Foundation FieldbusNo
Nominal output current I2N2.7A
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPYes
Application in industrial area permittedYes
Max. output at quadratic load at rated output voltage1.5kW
4-quadrant operation possibleYes
Max. output at linear load at rated output voltage1.5kW
Max. output frequency599Hz
Number of interfaces PROFINET0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV320U15S6C | Frek.pr. 1.5KW 600V 3PH-ATV320 Kompakt

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage switchgear and control gear (automation)
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of digital inputs

6

Width

105mm

With control element

Supporting protocol for LON

Height

142mm

Number of analogue outputs

1

Depth

158mm

Number of analogue inputs

3

Number of HW-interfaces industrial Ethernet

0

Number of digital outputs

1

Supporting protocol for PROFIBUS

Number of HW-interfaces RS-485

1

Supporting protocol for Data-Highway

Number of HW-interfaces USB

0

Number of HW-interfaces serial TTY

0

Supporting protocol for TCP/IP

Number of HW-interfaces other

1

Mains voltage

525 .. 600V

Number of HW-interfaces parallel

0

With optical interface

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

Supporting protocol for ASI

Degree of protection (IP)

IP20

Supporting protocol for SUCONET

Supporting protocol for CAN

Supporting protocol for DeviceNet

Supporting protocol for other bus systems

Number of HW-interfaces RS-232

0

Supporting protocol for KNX

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Mains frequency

50/60 Hz

With PC connection

Number of HW-interfaces RS-422

0

Degree of protection (NEMA)

1

Number of phases input

3

Number of phases output

3

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for DeviceNet Safety

Max. output voltage

600V

Type of converter

U converter

Supporting protocol for BACnet

Application in domestic- and commercial area permitted

Relative symmetric net voltage tolerance

10%

Relative symmetric net frequency tolerance

5%

Supporting protocol for AS-Interface Safety at Work

Integrated breaking resistance

Supporting protocol for Foundation Fieldbus

Nominal output current I2N

2.7A

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Application in industrial area permitted

Max. output at quadratic load at rated output voltage

1.5kW

4-quadrant operation possible

Max. output at linear load at rated output voltage

1.5kW

Max. output frequency

599Hz

Number of interfaces PROFINET

0

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.