Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of digital outputs1
With control elementYes
Height184mm
Width140mm
Depth158mm
Number of digital inputs6
Number of analogue inputs3
Supporting protocol for LONNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces other1
Number of analogue outputs1
Number of HW-interfaces parallel0
Number of HW-interfaces USB0
Number of HW-interfaces RS-4851
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Degree of protection (IP)IP20
Supporting protocol for ASINo
With PC connectionYes
Supporting protocol for ModbusYes
Supporting protocol for DeviceNetYes
Supporting protocol for KNXNo
Supporting protocol for SERCOSNo
Supporting protocol for other bus systemsYes
Supporting protocol for CANYes
Supporting protocol for INTERBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for TCP/IPYes
With optical interfaceNo
Supporting protocol for PROFIBUSYes
Supporting protocol for SUCONETNo
Number of interfaces PROFINET0
Mains frequency50/60 Hz
Supporting protocol for INTERBUS-SafetyNo
Mains voltage525 - 600V
Type of converterU converter
Number of phases output3
Integrated breaking resistanceYes
4-quadrant operation possibleYes
Number of phases input3
Supporting protocol for PROFINET IOYes
Max. output at linear load at rated output voltage4kW
Supporting protocol for SafetyBUS pNo
Max. output at quadratic load at rated output voltage4kW
Relative symmetric net voltage tolerance10%
Relative symmetric net frequency tolerance5%
Supporting protocol for PROFIsafeNo
Application in domestic- and commercial area permittedNo
Supporting protocol for PROFINET CBANo
Application in industrial area permittedYes
Supporting protocol for Foundation FieldbusNo
Max. output voltage600V
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPYes
Max. output frequency599Hz
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for BACnetNo
Degree of protection (NEMA)1
Nominal output current I2N6.1A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV320U40S6C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of digital outputs

1

With control element

Height

184mm

Width

140mm

Depth

158mm

Number of digital inputs

6

Number of analogue inputs

3

Supporting protocol for LON

Number of HW-interfaces serial TTY

0

Number of HW-interfaces other

1

Number of analogue outputs

1

Number of HW-interfaces parallel

0

Number of HW-interfaces USB

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-422

0

Degree of protection (IP)

IP20

Supporting protocol for ASI

With PC connection

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for KNX

Supporting protocol for SERCOS

Supporting protocol for other bus systems

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for Data-Highway

Supporting protocol for TCP/IP

With optical interface

Supporting protocol for PROFIBUS

Supporting protocol for SUCONET

Number of interfaces PROFINET

0

Mains frequency

50/60 Hz

Supporting protocol for INTERBUS-Safety

Mains voltage

525 .. 600V

Type of converter

U converter

Number of phases output

3

Integrated breaking resistance

4-quadrant operation possible

Number of phases input

3

Supporting protocol for PROFINET IO

Max. output at linear load at rated output voltage

4kW

Supporting protocol for SafetyBUS p

Max. output at quadratic load at rated output voltage

4kW

Relative symmetric net voltage tolerance

10%

Relative symmetric net frequency tolerance

5%

Supporting protocol for PROFIsafe

Application in domestic- and commercial area permitted

Supporting protocol for PROFINET CBA

Application in industrial area permitted

Supporting protocol for Foundation Fieldbus

Max. output voltage

600V

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

Max. output frequency

599Hz

Supporting protocol for DeviceNet Safety

Supporting protocol for BACnet

Degree of protection (NEMA)

1

Nominal output current I2N

6.1A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.