Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

With control elementYes
Supporting protocol for LONNo
Number of analogue inputs3
Number of HW-interfaces industrial Ethernet1
Depth225mm
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Height345mm
Number of analogue outputs2
Number of HW-interfaces RS-4220
Width155mm
Number of HW-interfaces RS-4851
Number of HW-interfaces parallel0
Number of HW-interfaces RS-2320
Number of digital outputs0
Number of digital inputs6
Supporting protocol for SERCOSNo
Number of HW-interfaces other0
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SUCONETNo
Supporting protocol for CANNo
Number of interfaces PROFINET0
4-quadrant operation possibleYes
Supporting protocol for DeviceNetYes
Number of phases output3
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusYes
Degree of protection (IP)IP20
Type of converterU converter
Supporting protocol for KNXNo
Supporting protocol for TCP/IPYes
Mains voltage380 - 480V
Supporting protocol for PROFIBUSYes
With PC connectionNo
Mains frequency50/60 Hz
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
With optical interfaceNo
Supporting protocol for other bus systemsNo
Number of phases input3
Integrated breaking resistanceNo
Supporting protocol for PROFINET CBANo
Max. output at quadratic load at rated output voltage7.5kW
Relative symmetric net voltage tolerance10%
Max. output at linear load at rated output voltage7.5kW
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFIsafeNo
Nominal output current I2N16.5A
Supporting protocol for SafetyBUS pNo
Max. output voltage480V
Supporting protocol for BACnetNo
Max. output frequency500Hz
Application in domestic- and commercial area permittedYes
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net frequency tolerance5%
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPYes
Application in industrial area permittedYes
Supporting protocol for Foundation FieldbusNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV630U75N4Z | FR Pret. IP21 7,5KW 400V Integracijski

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

With control element

Supporting protocol for LON

Number of analogue inputs

3

Number of HW-interfaces industrial Ethernet

1

Depth

225mm

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Height

345mm

Number of analogue outputs

2

Number of HW-interfaces RS-422

0

Width

155mm

Number of HW-interfaces RS-485

1

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-232

0

Number of digital outputs

0

Number of digital inputs

6

Supporting protocol for SERCOS

Number of HW-interfaces other

0

Supporting protocol for INTERBUS-Safety

Supporting protocol for SUCONET

Supporting protocol for CAN

Number of interfaces PROFINET

0

4-quadrant operation possible

Supporting protocol for DeviceNet

Number of phases output

3

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Degree of protection (IP)

IP20

Type of converter

U converter

Supporting protocol for KNX

Supporting protocol for TCP/IP

Mains voltage

380 .. 480V

Supporting protocol for PROFIBUS

With PC connection

Mains frequency

50/60 Hz

Supporting protocol for INTERBUS

Supporting protocol for ASI

With optical interface

Supporting protocol for other bus systems

Number of phases input

3

Integrated breaking resistance

Supporting protocol for PROFINET CBA

Max. output at quadratic load at rated output voltage

7.5kW

Relative symmetric net voltage tolerance

10%

Max. output at linear load at rated output voltage

7.5kW

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Nominal output current I2N

16.5A

Supporting protocol for SafetyBUS p

Max. output voltage

480V

Supporting protocol for BACnet

Max. output frequency

500Hz

Application in domestic- and commercial area permitted

Supporting protocol for DeviceNet Safety

Relative symmetric net frequency tolerance

5%

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

Application in industrial area permitted

Supporting protocol for Foundation Fieldbus

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.