Technical specifications

Depth393mm
Width320mm
Height852mm
Number of HW-interfaces RS-2320
Number of digital inputs8
Number of analogue inputs3
Supporting protocol for LONNo
Number of digital outputs1
Number of HW-interfaces industrial Ethernet0
With control elementYes
Number of HW-interfaces RS-4220
Number of analogue outputs2
Supporting protocol for TCP/IPNo
With optical interfaceYes
Supporting protocol for PROFIBUSYes
Supporting protocol for SUCONETNo
Number of HW-interfaces USB0
Number of HW-interfaces RS-4853
Supporting protocol for DeviceNetYes
Supporting protocol for ASINo
Supporting protocol for CANYes
Number of HW-interfaces serial TTY0
Number of HW-interfaces other0
Supporting protocol for ModbusNo
Number of HW-interfaces parallel0
Supporting protocol for INTERBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for KNXNo
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP00
4-quadrant operation possibleYes
Mains frequency50/60 Hz
Mains voltage380 - 480V
Supporting protocol for other bus systemsYes
With PC connectionNo
Supporting protocol for SERCOSNo
Number of interfaces PROFINET0
Max. output at quadratic load at rated output voltage110kW
Integrated breaking resistanceNo
Max. output frequency500Hz
Max. output at linear load at rated output voltage110kW
Supporting protocol for EtherNet/IPYes
Application in domestic- and commercial area permittedYes
Application in industrial area permittedYes
Type of converterU converter
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Relative symmetric net frequency tolerance5%
Number of phases input3
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net voltage tolerance10%
Number of phases output3
Supporting protocol for SafetyBUS pNo
Max. output voltage480V
Nominal output current I2N211A
Supporting protocol for BACnetNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFIsafeNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV930C11N4 | Frek. Pret. IP21 110KW 400/480V

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth

393mm

Width

320mm

Height

852mm

Number of HW-interfaces RS-232

0

Number of digital inputs

8

Number of analogue inputs

3

Supporting protocol for LON

Number of digital outputs

1

Number of HW-interfaces industrial Ethernet

0

With control element

Number of HW-interfaces RS-422

0

Number of analogue outputs

2

Supporting protocol for TCP/IP

With optical interface

Supporting protocol for PROFIBUS

Supporting protocol for SUCONET

Number of HW-interfaces USB

0

Number of HW-interfaces RS-485

3

Supporting protocol for DeviceNet

Supporting protocol for ASI

Supporting protocol for CAN

Number of HW-interfaces serial TTY

0

Number of HW-interfaces other

0

Supporting protocol for Modbus

Number of HW-interfaces parallel

0

Supporting protocol for INTERBUS

Supporting protocol for Data-Highway

Supporting protocol for KNX

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP00

4-quadrant operation possible

Mains frequency

50/60 Hz

Mains voltage

380 .. 480V

Supporting protocol for other bus systems

With PC connection

Supporting protocol for SERCOS

Number of interfaces PROFINET

0

Max. output at quadratic load at rated output voltage

110kW

Integrated breaking resistance

Max. output frequency

500Hz

Max. output at linear load at rated output voltage

110kW

Supporting protocol for EtherNet/IP

Application in domestic- and commercial area permitted

Application in industrial area permitted

Type of converter

U converter

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Relative symmetric net frequency tolerance

5%

Number of phases input

3

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net voltage tolerance

10%

Number of phases output

3

Supporting protocol for SafetyBUS p

Max. output voltage

480V

Nominal output current I2N

211A

Supporting protocol for BACnet

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.