Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

With control elementYes
Depth225.5mm
Width195mm
Height480mm
Number of analogue outputs2
Number of digital inputs8
Number of digital outputs1
Number of analogue inputs3
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-2320
With optical interfaceNo
Number of HW-interfaces other0
Number of HW-interfaces USB0
Supporting protocol for ModbusNo
Number of HW-interfaces industrial Ethernet0
Supporting protocol for LONNo
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
Number of HW-interfaces serial TTY0
Supporting protocol for SUCONETNo
Supporting protocol for PROFIBUSYes
Supporting protocol for TCP/IPNo
Supporting protocol for other bus systemsYes
Supporting protocol for KNXNo
Number of HW-interfaces parallel0
Supporting protocol for Data-HighwayNo
Number of HW-interfaces RS-4853
Supporting protocol for DeviceNetYes
Supporting protocol for CANYes
With PC connectionNo
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP20
Supporting protocol for SERCOSNo
Supporting protocol for AS-Interface Safety at WorkNo
Integrated breaking resistanceNo
Mains voltage380 - 480V
Application in domestic- and commercial area permittedYes
Number of phases output3
Number of interfaces PROFINET0
Max. output at linear load at rated output voltage18.5kW
Mains frequency50/60 Hz
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net voltage tolerance10%
Number of phases input3
Max. output frequency500Hz
Application in industrial area permittedYes
Max. output at quadratic load at rated output voltage18.5kW
Relative symmetric net frequency tolerance5%
Type of converterU converter
4-quadrant operation possibleYes
Supporting protocol for EtherNet/IPYes
Nominal output current I2N39.2A
Supporting protocol for PROFIsafeNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Max. output voltage480V
Supporting protocol for PROFINET IOYes
Supporting protocol for BACnetNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV930D18N4Z | Frek. Pret IP21 18,5KW 400v/480v bez dis

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

With control element

Depth

225.5mm

Width

195mm

Height

480mm

Number of analogue outputs

2

Number of digital inputs

8

Number of digital outputs

1

Number of analogue inputs

3

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-232

0

With optical interface

Number of HW-interfaces other

0

Number of HW-interfaces USB

0

Supporting protocol for Modbus

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for LON

Supporting protocol for ASI

Supporting protocol for INTERBUS

Number of HW-interfaces serial TTY

0

Supporting protocol for SUCONET

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Supporting protocol for other bus systems

Supporting protocol for KNX

Number of HW-interfaces parallel

0

Supporting protocol for Data-Highway

Number of HW-interfaces RS-485

3

Supporting protocol for DeviceNet

Supporting protocol for CAN

With PC connection

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP20

Supporting protocol for SERCOS

Supporting protocol for AS-Interface Safety at Work

Integrated breaking resistance

Mains voltage

380 .. 480V

Application in domestic- and commercial area permitted

Number of phases output

3

Number of interfaces PROFINET

0

Max. output at linear load at rated output voltage

18.5kW

Mains frequency

50/60 Hz

Supporting protocol for DeviceNet Safety

Relative symmetric net voltage tolerance

10%

Number of phases input

3

Max. output frequency

500Hz

Application in industrial area permitted

Max. output at quadratic load at rated output voltage

18.5kW

Relative symmetric net frequency tolerance

5%

Type of converter

U converter

4-quadrant operation possible

Supporting protocol for EtherNet/IP

Nominal output current I2N

39.2A

Supporting protocol for PROFIsafe

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Max. output voltage

480V

Supporting protocol for PROFINET IO

Supporting protocol for BACnet

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.