Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of analogue inputs3
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces USB0
Depth325.5mm
Number of HW-interfaces other0
Supporting protocol for LONNo
Number of HW-interfaces parallel0
Width290mm
Number of HW-interfaces RS-4853
Height922mm
Number of digital outputs1
Number of HW-interfaces serial TTY0
Number of digital inputs8
Number of analogue outputs2
With optical interfaceNo
Number of HW-interfaces RS-2320
With control elementYes
Number of HW-interfaces RS-4220
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusNo
Supporting protocol for CANYes
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSYes
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Supporting protocol for Data-HighwayNo
Supporting protocol for SERCOSNo
With PC connectionNo
Mains voltage380 - 480V
Number of phases output3
Supporting protocol for INTERBUS-SafetyNo
4-quadrant operation possibleYes
Number of phases input3
Type of converterU converter
Mains frequency50/60 Hz
Integrated breaking resistanceNo
Degree of protection (IP)IP21
Number of interfaces PROFINET0
Supporting protocol for other bus systemsYes
Supporting protocol for SUCONETNo
Max. output at quadratic load at rated output voltage75kW
Application in domestic- and commercial area permittedYes
Max. output frequency500Hz
Application in industrial area permittedYes
Supporting protocol for DeviceNet SafetyNo
Max. output at linear load at rated output voltage75kW
Relative symmetric net frequency tolerance5%
Relative symmetric net voltage tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNetYes
Max. output voltage480V
Supporting protocol for Foundation FieldbusNo
Nominal output current I2N145A
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Supporting protocol for BACnetNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET IOYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV930D75N4C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of analogue inputs

3

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces USB

0

Depth

325.5mm

Number of HW-interfaces other

0

Supporting protocol for LON

Number of HW-interfaces parallel

0

Width

290mm

Number of HW-interfaces RS-485

3

Height

922mm

Number of digital outputs

1

Number of HW-interfaces serial TTY

0

Number of digital inputs

8

Number of analogue outputs

2

With optical interface

Number of HW-interfaces RS-232

0

With control element

Number of HW-interfaces RS-422

0

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for CAN

Supporting protocol for KNX

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Supporting protocol for ASI

Supporting protocol for Data-Highway

Supporting protocol for SERCOS

With PC connection

Mains voltage

380 .. 480V

Number of phases output

3

Supporting protocol for INTERBUS-Safety

4-quadrant operation possible

Number of phases input

3

Type of converter

U converter

Mains frequency

50/60 Hz

Integrated breaking resistance

Degree of protection (IP)

IP21

Number of interfaces PROFINET

0

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Max. output at quadratic load at rated output voltage

75kW

Application in domestic- and commercial area permitted

Max. output frequency

500Hz

Application in industrial area permitted

Supporting protocol for DeviceNet Safety

Max. output at linear load at rated output voltage

75kW

Relative symmetric net frequency tolerance

5%

Relative symmetric net voltage tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet

Max. output voltage

480V

Supporting protocol for Foundation Fieldbus

Nominal output current I2N

145A

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Supporting protocol for BACnet

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.