Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width155mm
Depth225mm
Number of HW-interfaces RS-4220
Number of HW-interfaces serial TTY0
Number of digital inputs8
Number of HW-interfaces RS-2320
Number of digital outputs1
Number of analogue inputs3
With control elementYes
Number of HW-interfaces industrial Ethernet0
Supporting protocol for LONNo
Number of HW-interfaces RS-4853
Number of analogue outputs2
Supporting protocol for PROFIBUSYes
Supporting protocol for TCP/IPNo
Supporting protocol for CANYes
Supporting protocol for ASINo
Number of HW-interfaces other0
Number of HW-interfaces USB0
Number of HW-interfaces parallel0
Supporting protocol for KNXNo
Supporting protocol for INTERBUSNo
With optical interfaceNo
Supporting protocol for ModbusNo
Height345mm
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetYes
Mains frequency50/60 Hz
Type of converterU converter
Number of interfaces PROFINET0
Supporting protocol for SERCOSNo
Number of phases output3
Degree of protection (IP)IP20
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUS-SafetyNo
Mains voltage380 - 480V
Supporting protocol for other bus systemsYes
4-quadrant operation possibleYes
Integrated breaking resistanceNo
Supporting protocol for AS-Interface Safety at WorkNo
Max. output frequency500Hz
Application in industrial area permittedYes
Application in domestic- and commercial area permittedYes
Max. output at linear load at rated output voltage7.5kW
Relative symmetric net voltage tolerance10%
Max. output at quadratic load at rated output voltage7.5kW
Number of phases input3
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPYes
With PC connectionNo
Relative symmetric net frequency tolerance5%
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IOYes
Nominal output current I2N16.5A
Supporting protocol for BACnetNo
Supporting protocol for PROFIsafeNo
Max. output voltage480V
Supporting protocol for SafetyBUS pNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV930U75N4Z

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

155mm

Depth

225mm

Number of HW-interfaces RS-422

0

Number of HW-interfaces serial TTY

0

Number of digital inputs

8

Number of HW-interfaces RS-232

0

Number of digital outputs

1

Number of analogue inputs

3

With control element

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for LON

Number of HW-interfaces RS-485

3

Number of analogue outputs

2

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Supporting protocol for CAN

Supporting protocol for ASI

Number of HW-interfaces other

0

Number of HW-interfaces USB

0

Number of HW-interfaces parallel

0

Supporting protocol for KNX

Supporting protocol for INTERBUS

With optical interface

Supporting protocol for Modbus

Height

345mm

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Mains frequency

50/60 Hz

Type of converter

U converter

Number of interfaces PROFINET

0

Supporting protocol for SERCOS

Number of phases output

3

Degree of protection (IP)

IP20

Supporting protocol for SUCONET

Supporting protocol for INTERBUS-Safety

Mains voltage

380 .. 480V

Supporting protocol for other bus systems

4-quadrant operation possible

Integrated breaking resistance

Supporting protocol for AS-Interface Safety at Work

Max. output frequency

500Hz

Application in industrial area permitted

Application in domestic- and commercial area permitted

Max. output at linear load at rated output voltage

7.5kW

Relative symmetric net voltage tolerance

10%

Max. output at quadratic load at rated output voltage

7.5kW

Number of phases input

3

Supporting protocol for DeviceNet Safety

Supporting protocol for EtherNet/IP

With PC connection

Relative symmetric net frequency tolerance

5%

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Nominal output current I2N

16.5A

Supporting protocol for BACnet

Supporting protocol for PROFIsafe

Max. output voltage

480V

Supporting protocol for SafetyBUS p

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.