Aleta.hr

Details

  • Programmable logic controllers PLC
  • PLC CPU-module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Supply voltage AC 50 Hz0 - 0V
Supply voltage AC 60 Hz0 - 0V
Supply voltage DC24 - 24V
Max. number of time switches0
Number of HW-interfaces industrial Ethernet4
ModelModular
Processing time (1K, binary operation)0.1ms
Voltage type of supply voltageDC
Number of HW-interfaces RS-2320
Number of interfaces PROFINET0
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4850
Number of HW-interfaces USB1
Number of HW-interfaces parallel0
Number of analogue outputs0
Number of relay outputs0
Number of digital inputs0
Number of analogue inputs0
Number of HW-interfaces Wireless0
Supporting protocol for PROFIBUSNo
With optical interfaceNo
Supporting protocol for INTERBUSNo
Supporting protocol for CANNo
Supporting protocol for KNXNo
Supporting protocol for ASIYes
Number of digital outputs0
Number of HW-interfaces other0
Supporting protocol for ModbusNo
Supporting protocol for DeviceNetNo
Supporting protocol for LONNo
Supporting protocol for SUCONETNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for TCP/IPYes
Supporting protocol for EtherNet/IPYes
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SafetyBUS pNo
Radio standard GSMNo
Radio standard UMTSNo
Long-Term Evolution (LTE)No
IO link masterYes
System accessoryNo
RedundancyYes
With displayNo
Memory size8192kByte
Type of memoryRAM
Additional program memory possibleYes
Rail mounting possibleNo
Wall mounting/direct mountingNo
Rack-assembly possibleYes
Front built-in possibleNo
Suitable for safety functionsYes
Performance level according to EN ISO 13849-1None
SIL according to IEC 61508None
Appendant operation agent (Ex ib)No
Explosion safety category for gasATEX gas-ex-protection, Cat. 3G
Explosion safety category for dustATEX dust-ex-protection, Cat. 3D
Appendant operation agent (Ex ia)No
Width64.6mm
Height134.6mm
Depth130.3mm
Supporting protocol for other bus systemsNo
Supporting protocol for IEC 60870No
Supporting protocol for DNP3No
Supporting protocol for IEC 61850 EthernetNo
Radio standard BluetoothNo
Radio standard Wi-Fi 802.11No
Radio standard GPRSNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BMEH582040S

Main Product Image

Details

  • Programmable logic controllers PLC
  • PLC CPU-module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Supply voltage AC 50 Hz

0 .. 0V

Supply voltage AC 60 Hz

0 .. 0V

Supply voltage DC

24 .. 24V

Max. number of time switches

0

Number of HW-interfaces industrial Ethernet

4

Model

Modular

Processing time (1K, binary operation)

0.1ms

Voltage type of supply voltage

DC

Number of HW-interfaces RS-232

0

Number of interfaces PROFINET

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

0

Number of HW-interfaces USB

1

Number of HW-interfaces parallel

0

Number of analogue outputs

0

Number of relay outputs

0

Number of digital inputs

0

Number of analogue inputs

0

Number of HW-interfaces Wireless

0

Supporting protocol for PROFIBUS

With optical interface

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for KNX

Supporting protocol for ASI

Number of digital outputs

0

Number of HW-interfaces other

0

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for LON

Supporting protocol for SUCONET

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for TCP/IP

Supporting protocol for EtherNet/IP

Supporting protocol for SERCOS

Supporting protocol for Foundation Fieldbus

Supporting protocol for Data-Highway

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for DeviceNet Safety

Supporting protocol for SafetyBUS p

Radio standard GSM

Radio standard UMTS

Long-Term Evolution (LTE)

IO link master

System accessory

Redundancy

With display

Memory size

8192kByte

Type of memory

RAM

Additional program memory possible

Rail mounting possible

Wall mounting/direct mounting

Rack-assembly possible

Front built-in possible

Suitable for safety functions

Performance level according to EN ISO 13849-1

None

SIL according to IEC 61508

None

Appendant operation agent (Ex ib)

Explosion safety category for gas

ATEX gas-ex-protection, Cat. 3G

Explosion safety category for dust

ATEX dust-ex-protection, Cat. 3D

Appendant operation agent (Ex ia)

Width

64.6mm

Height

134.6mm

Depth

130.3mm

Supporting protocol for other bus systems

Supporting protocol for IEC 60870

Supporting protocol for DNP3

Supporting protocol for IEC 61850 Ethernet

Radio standard Bluetooth

Radio standard Wi-Fi 802.11

Radio standard GPRS

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.