Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at DC- - -V
Rated conditional short-circuit current, type 2, 400 V-A
Rated power, 575 V, 60 Hz, 3-phase-kW
Rated conditional short-circuit current, type 2, 230 V-A
Rated operation power at AC-3, 230 V, 3-phase3kW
Rated power, 460 V, 60 Hz, 3-phase5.5kW
Overload release current setting9 - 14A
Rated operation power at AC-3, 400 V5.5kW
Rated conditional short-circuit current, type 1, 480 Y/277 V6000A
Voltage type for actuatingAC
Rated control supply voltage Us at AC 50HZ220 - 220V
With short-circuit releaseYes
Rated operation current Ie12A
Rated control supply voltage Us at AC 60HZ220 - 220V
Type of motor starterDirect online starter (DOL)
Number of auxiliary contacts as normally open contact0
Ambient temperature, upper operating limit40°C
Rated conditional short-circuit current, type 1, 600 Y/347 V3000A
Release classCLASS 10
Temperature compensated overload protectionYes
Type of electrical connection of main circuitScrew connection
Rail mounting possibleNo
Suitable for emergency stopYes
Coordination class according to IEC 60947-4-3Class 1
Type of electrical connection for auxiliary- and control current circuitScrew connection
With transformerNo
Number of command positions5
Number of auxiliary contacts as normally closed contact0
External reset possibleNo
Rated operation current at AC-3, 400 V12A
Number of indicator lights0
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSNo
Degree of protection (IP)IP55
With fuseNo
Supporting protocol for ModbusNo
Supporting protocol for TCP/IPNo
Supporting protocol for CANNo
Supporting protocol for Data-HighwayNo
Supporting protocol for ASINo
Supporting protocol for PROFINET IONo
Supporting protocol for LONNo
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetNo
Width175mm
Height165mm
Depth165mm
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET CBANo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for other bus systemsNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SafetyBUS pNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LG1D122M716

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at DC

- .. -V

Rated conditional short-circuit current, type 2, 400 V

-A

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 2, 230 V

-A

Rated operation power at AC-3, 230 V, 3-phase

3kW

Rated power, 460 V, 60 Hz, 3-phase

5.5kW

Overload release current setting

9 .. 14A

Rated operation power at AC-3, 400 V

5.5kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

6000A

Voltage type for actuating

AC

Rated control supply voltage Us at AC 50HZ

220 .. 220V

With short-circuit release

Rated operation current Ie

12A

Rated control supply voltage Us at AC 60HZ

220 .. 220V

Type of motor starter

Direct online starter (DOL)

Number of auxiliary contacts as normally open contact

0

Ambient temperature, upper operating limit

40°C

Rated conditional short-circuit current, type 1, 600 Y/347 V

3000A

Release class

CLASS 10

Temperature compensated overload protection

Type of electrical connection of main circuit

Screw connection

Rail mounting possible

Suitable for emergency stop

Coordination class according to IEC 60947-4-3

Class 1

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With transformer

Number of command positions

5

Number of auxiliary contacts as normally closed contact

0

External reset possible

Rated operation current at AC-3, 400 V

12A

Number of indicator lights

0

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Degree of protection (IP)

IP55

With fuse

Supporting protocol for Modbus

Supporting protocol for TCP/IP

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for ASI

Supporting protocol for PROFINET IO

Supporting protocol for LON

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Width

175mm

Height

165mm

Depth

165mm

Supporting protocol for SERCOS

Supporting protocol for PROFINET CBA

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for other bus systems

Supporting protocol for DeviceNet Safety

Supporting protocol for SafetyBUS p

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.