Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Supporting protocol for LONNo
Width45mm
Number of auxiliary contacts as normally open contact1
Height224mm
Rated operation power at AC-3, 400 V18.5kW
Number of command positions3
Number of indicator lights0
With transformerNo
Rated operation current Ie38A
Number of auxiliary contacts as normally closed contact1
Depth126mm
Suitable for emergency stopNo
Supporting protocol for TCP/IPNo
Rail mounting possibleYes
Supporting protocol for ModbusNo
With fuseNo
Supporting protocol for PROFIBUSNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for other bus systemsNo
Rated control supply voltage Us at AC 60HZ110 - 240V
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for SUCONETNo
Rated control supply voltage Us at AC 50HZ110 - 240V
Supporting protocol for Data-HighwayNo
Rated control supply voltage Us at DC110 - 220V
External reset possibleNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
With short-circuit releaseYes
Degree of protection (IP)IP20
Supporting protocol for SERCOSNo
Supporting protocol for DeviceNetNo
Supporting protocol for CANNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET CBANo
Rated power, 575 V, 60 Hz, 3-phase18.5kW
Rated operation power at AC-3, 230 V, 3-phase9kW
Type of motor starterReversing starter
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IONo
Voltage type for actuatingAC/DC
Rated operation current at AC-3, 400 V38A
Rated conditional short-circuit current, type 2, 230 V25000A
Coordination class according to IEC 60947-4-3Class 2
Ambient temperature, upper operating limit70°C
Rated conditional short-circuit current, type 1, 480 Y/277 V10000A
Rated conditional short-circuit current, type 2, 400 V25000A
Rated conditional short-circuit current, type 1, 600 Y/347 V4000A
Rated power, 460 V, 60 Hz, 3-phase18.5kW
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LU2B38FU | Baza 2 Smjera 38A 110-240V Ac/dc

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Supporting protocol for LON

Width

45mm

Number of auxiliary contacts as normally open contact

1

Height

224mm

Rated operation power at AC-3, 400 V

18.5kW

Number of command positions

3

Number of indicator lights

0

With transformer

Rated operation current Ie

38A

Number of auxiliary contacts as normally closed contact

1

Depth

126mm

Suitable for emergency stop

Supporting protocol for TCP/IP

Rail mounting possible

Supporting protocol for Modbus

With fuse

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS-Safety

Supporting protocol for other bus systems

Rated control supply voltage Us at AC 60HZ

110 .. 240V

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for SUCONET

Rated control supply voltage Us at AC 50HZ

110 .. 240V

Supporting protocol for Data-Highway

Rated control supply voltage Us at DC

110 .. 220V

External reset possible

Type of electrical connection of main circuit

Screw connection

Supporting protocol for ASI

Supporting protocol for INTERBUS

With short-circuit release

Degree of protection (IP)

IP20

Supporting protocol for SERCOS

Supporting protocol for DeviceNet

Supporting protocol for CAN

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET CBA

Rated power, 575 V, 60 Hz, 3-phase

18.5kW

Rated operation power at AC-3, 230 V, 3-phase

9kW

Type of motor starter

Reversing starter

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Voltage type for actuating

AC/DC

Rated operation current at AC-3, 400 V

38A

Rated conditional short-circuit current, type 2, 230 V

25000A

Coordination class according to IEC 60947-4-3

Class 2

Ambient temperature, upper operating limit

70°C

Rated conditional short-circuit current, type 1, 480 Y/277 V

10000A

Rated conditional short-circuit current, type 2, 400 V

25000A

Rated conditional short-circuit current, type 1, 600 Y/347 V

4000A

Rated power, 460 V, 60 Hz, 3-phase

18.5kW

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.