Technical specifications

Height154mm
With transformerNo
Depth126mm
Number of command positions3
Width45mm
Number of auxiliary contacts as normally open contact1
Number of auxiliary contacts as normally closed contact1
Number of indicator lights0
Suitable for emergency stopNo
Supporting protocol for INTERBUSNo
Supporting protocol for LONNo
Supporting protocol for CANNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Supporting protocol for TCP/IPNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
Rail mounting possibleYes
Supporting protocol for ModbusNo
External reset possibleNo
Supporting protocol for DeviceNetNo
Rated control supply voltage Us at AC 50HZ24 - 240V
Rated control supply voltage Us at AC 60HZ24 - 240V
With short-circuit releaseYes
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Supporting protocol for PROFIsafeNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
With fuseNo
Supporting protocol for PROFINET IONo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Supporting protocol for EtherNet/IPNo
Type of electrical connection of main circuitScrew connection
Rated operation power at AC-3, 230 V, 3-phase9kW
Rated conditional short-circuit current, type 2, 400 V25000A
Rated power, 575 V, 60 Hz, 3-phase18.5kW
Rated conditional short-circuit current, type 1, 600 Y/347 V4000A
Rated power, 460 V, 60 Hz, 3-phase18.5kW
Rated conditional short-circuit current, type 1, 480 Y/277 V10000A
Voltage type for actuatingAC/DC
Rated conditional short-circuit current, type 2, 230 V25000A
Ambient temperature, upper operating limit70°C
Coordination class according to IEC 60947-4-3Class 2
Rated operation power at AC-3, 400 V18.5kW
Rated operation current Ie38A
Degree of protection (IP)IP20
Rated control supply voltage Us at DC24 - 220V
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V38A