Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)IP40
Type of control elementToggle
Number of poles4
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu40A
Motor drive integratedNo
Rated voltage690 - 690V
Overload release current setting28 - 40A
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as change-over contact0
Motor drive optionalNo
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release600 - 600A
Suitable for DIN rail (top hat rail) mountingYes
With under voltage releaseNo
With switched-off indicatorYes
Adjustment range short-term delayed short-circuit release- - -A
Position of connection for main current circuitFront side
Integrated earth fault protectionNo
Complete device with protection unitYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LV426273

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP40

Type of control element

Toggle

Number of poles

4

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

40A

Motor drive integrated

Rated voltage

690 .. 690V

Overload release current setting

28 .. 40A

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as change-over contact

0

Motor drive optional

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

600 .. 600A

Suitable for DIN rail (top hat rail) mounting

With under voltage release

With switched-off indicator

Adjustment range short-term delayed short-circuit release

- .. -A

Position of connection for main current circuit

Front side

Integrated earth fault protection

Complete device with protection unit

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

DIN rail (top hat rail) mounting optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.