Details
- •Low-voltage industrial components
- •Motor starter/Motor starter combination
- •1 KOM
- •SCHNEIDER
Technical specifications
LJ7K06Q708 | Pokretac Motorski 2.5-4 98/37/CE

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Width
175mm
Depth
177mm
Number of command positions
4
Rated operation power at AC-3, 400 V
1.5kW
Height
165mm
With transformer
Number of auxiliary contacts as normally open contact
0
Number of indicator lights
0
Suitable for emergency stop
Supporting protocol for TCP/IP
Number of auxiliary contacts as normally closed contact
0
Supporting protocol for LON
Overload release current setting
2.5 .. 4A
Rated operation current Ie
4A
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
Supporting protocol for Modbus
Supporting protocol for INTERBUS
Rail mounting possible
Rated control supply voltage Us at AC 60HZ
24 .. 24V
Rated control supply voltage Us at DC
- .. -V
Supporting protocol for CAN
Supporting protocol for ASI
Supporting protocol for SUCONET
Supporting protocol for SERCOS
Supporting protocol for PROFIBUS
External reset possible
Degree of protection (IP)
IP55
Supporting protocol for other bus systems
Rated control supply voltage Us at AC 50HZ
24 .. 24V
Supporting protocol for DeviceNet Safety
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for AS-Interface Safety at Work
Release class
CLASS 10
With short-circuit release
Supporting protocol for INTERBUS-Safety
Type of electrical connection of main circuit
Screw connection
Supporting protocol for EtherNet/IP
With fuse
Rated operation power at AC-3, 230 V, 3-phase
-kW
Supporting protocol for PROFINET IO
Rated power, 460 V, 60 Hz, 3-phase
-kW
Supporting protocol for PROFINET CBA
Rated conditional short-circuit current, type 2, 230 V
-A
Voltage type for actuating
AC
Supporting protocol for PROFIsafe
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Supporting protocol for Foundation Fieldbus
Supporting protocol for SafetyBUS p
Type of motor starter
Direct online starter (DOL)
Temperature compensated overload protection
Rated conditional short-circuit current, type 2, 400 V
50000A
Ambient temperature, upper operating limit
40°C
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated operation current at AC-3, 400 V
4A
Coordination class according to IEC 60947-4-3