Technical specifications

Width175mm
Depth177mm
Number of command positions4
Height165mm
With transformerYes
Number of auxiliary contacts as normally open contact0
Number of indicator lights0
Suitable for emergency stopYes
Supporting protocol for TCP/IPNo
Number of auxiliary contacts as normally closed contact0
Supporting protocol for LONNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for ModbusNo
Supporting protocol for INTERBUSNo
Rail mounting possibleNo
Rated control supply voltage Us at AC 60HZ24 - 24V
Supporting protocol for CANNo
Supporting protocol for ASINo
Supporting protocol for SUCONETNo
Supporting protocol for SERCOSNo
Supporting protocol for PROFIBUSNo
External reset possibleNo
Supporting protocol for other bus systemsNo
Rated control supply voltage Us at AC 50HZ24 - 24V
Supporting protocol for DeviceNet SafetyNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
Release classCLASS 10
With short-circuit releaseYes
Supporting protocol for INTERBUS-SafetyNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for EtherNet/IPNo
With fuseNo
Rated operation power at AC-3, 230 V, 3-phase-kW
Supporting protocol for PROFINET IONo
Rated power, 460 V, 60 Hz, 3-phase-kW
Supporting protocol for PROFINET CBANo
Rated conditional short-circuit current, type 2, 230 V-A
Voltage type for actuatingAC
Supporting protocol for PROFIsafeNo
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SafetyBUS pNo
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 2, 400 V50000A
Ambient temperature, upper operating limit40°C
Rated power, 575 V, 60 Hz, 3-phase-kW
Coordination class according to IEC 60947-4-3Class 1
Rated operation power at AC-3, 400 V1.5kW
Rated operation current Ie4A
Overload release current setting2.5 - 4A
Degree of protection (IP)IP55
Rated control supply voltage Us at DC- - -V
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V4A