Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated current6A
Over voltage category4
Release characteristicB
Rated voltage277V
Built-in depth44mm
Current limiting class3
Voltage typeAC/DC
Pollution degree3
Frequency50 - 60Hz
Rated insulation voltage Ui500V
Ambient temperature during operating-30 - 70°C
Connectable conductor cross section multi-wired1 - 16mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V3kA
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Width in number of modular spacings2
Number of protected poles1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Number of poles (total)1
Flush-mounted installationNo
Degree of protection (IP)IP20
Concurrently switching neutral conductorYes
Explosion-proofNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated impulse withstand voltage Uimp6kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

M9F21106 | MULTI9 C60SP 1P B 6A 10KA 277V UL1077

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated current

6A

Over voltage category

4

Release characteristic

B

Rated voltage

277V

Built-in depth

44mm

Current limiting class

3

Voltage type

AC/DC

Pollution degree

3

Frequency

50 .. 60Hz

Rated insulation voltage Ui

500V

Ambient temperature during operating

-30 .. 70°C

Connectable conductor cross section multi-wired

1 .. 16mm²

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

3kA

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Width in number of modular spacings

2

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of poles (total)

1

Flush-mounted installation

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Explosion-proof

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated impulse withstand voltage Uimp

6kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.