Details
- •Relays
- •Device for monitoring of safety-related circuits
- •1 KOM
- •SCHNEIDER
Technical specifications
XPSCM1144P | Modulsigurn. Foto. TIP 2

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Relays
- Device for monitoring of safety-related circuits
- 1 KOM
- SCHNEIDER
Technical specifications
Power consumption
1.1W
Depth
114mm
Release-delay
0 .. 60s
Width
45mm
Model
Basic device
Height
99mm
Control voltage 2
24 .. 24V
Control voltage 1
24 .. 24V
Type of control voltage 2
DC
Type of control voltage 1
DC
With approval according to UL
With detachable clamps
Voltage type of supply voltage
DC
With feedback circuit
With start input
Number of outputs, safety related, delayed, with contact
0
Number of outputs, safety related, undelayed, semiconductors
0
Number of outputs, safety related, undelayed, with contact
2
Number of outputs, safety related, delayed, semiconductors
0
Number of outputs, signalling function, delayed, semiconductors
0
Number of outputs, signalling function, undelayed, semiconductors
0
Number of outputs, signalling function, delayed, with contact
0
Number of outputs, signalling function, undelayed, with contact
2
With muting function
With approval for BG BIA
Type of electric connection
Screw connection
Voltage type (operating voltage)
DC
Type of safety according to IEC 61496-1
1
Suitable for monitoring of magnetic switches
Suitable for monitoring of proximity switches
Suitable for monitoring of emergency-stop circuits
Rated switch current
1.1A
Suitable for monitoring of optoelectronic protection equipment
Suitable for monitoring of position switches
Suitable for monitoring of tactile sensors
Rail mounting possible
Suitable for monitoring of valves
Performance level according to EN ISO 13849-1
Level c
Supply voltage DC
24 .. 24V
Operating voltage at DC
24 .. 24V
Evaluation inputs
Other
Stop category according to IEC 60204
Other
SIL according to IEC 61508
1
With approval for TÜV