Number of outputs, safety related, undelayed, with contact8
With detachable clampsYes
With approval according to ULYes
Number of outputs, signalling function, delayed, semiconductors0
Rated control supply voltage Us at AC 50HZ- - -V
Number of outputs, signalling function, undelayed, with contact1
Number of outputs, signalling function, delayed, with contact0
Number of outputs, safety related, delayed, semiconductors0
Number of outputs, signalling function, undelayed, semiconductors1
Suitable for monitoring of tactile sensorsNo
Type of electric connectionScrew connection
Suitable for monitoring of magnetic switchesNo
Category according to EN 954-14
Rail mounting possibleYes
Suitable for monitoring of optoelectronic protection equipmentNo
Suitable for monitoring of valvesNo
With approval for BG BIANo
Number of outputs, safety related, undelayed, semiconductors0
Suitable for monitoring of position switchesNo
Rated control supply voltage Us at DC24 - 24V
Rated control supply voltage Us at AC 60HZ- - -V
Suitable for monitoring of proximity switchesNo
Number of outputs, safety related, delayed, with contact0
Suitable for monitoring of emergency-stop circuitsNo
Evaluation inputs2-channel
Voltage type for actuatingAC/DC
Stop category according to IEC 60204Other
SIL according to IEC 615083
Type of safety according to IEC 61496-11
Performance level according to EN ISO 13849-1Level e