Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Current limiting class3
Rated voltage240V
Frequency50 Hz
Leakage current typeA
Over voltage category3
Built-in depth75.5mm
Surge current capacity3kA
Rated insulation voltage Ui500V
Release characteristicB
Rated current40A
Pollution degree2
Voltage typeAC
Degree of protection (IP)IP20
Width in number of modular spacings2
Rated fault current0.1A
With interlocking deviceNo
Flush-mounted installationNo
Rated short-circuit breaking capacity according to IEC 60947-210kA
Number of protected poles1
Number of poles (total)2
Rated short-circuit breaking capacity according to EN 6100910kA
Connectable conductor cross section multi-wired1 - 25mm²
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Connectable conductor cross section solid-core1 - 25mm²
Ambient temperature during operating-25 - 40°C
Anti-nuisance tripping versionYes
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBmM-B40/1N/01-F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Current limiting class

3

Rated voltage

240V

Frequency

50 Hz

Leakage current type

A

Over voltage category

3

Built-in depth

75.5mm

Surge current capacity

3kA

Rated insulation voltage Ui

500V

Release characteristic

B

Rated current

40A

Pollution degree

2

Voltage type

AC

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Rated fault current

0.1A

With interlocking device

Flush-mounted installation

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Number of protected poles

1

Number of poles (total)

2

Rated short-circuit breaking capacity according to EN 61009

10kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Connectable conductor cross section solid-core

1 .. 25mm²

Ambient temperature during operating

-25 .. 40°C

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.