Technical specifications

Height200mm
Rated operation power at AC-3, 400 V4kW
Power consumption1.4W
Width45mm
With transformerNo
Depth154mm
Supporting protocol for LONNo
Supporting protocol for SERCOSNo
Rail mounting possibleNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for DeviceNetNo
External reset possibleNo
Supporting protocol for SUCONETNo
Number of indicator lights0
Suitable for emergency stopNo
Supporting protocol for ASINo
Supporting protocol for CANNo
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for INTERBUSNo
Overload release current setting6.3 - 10A
Supporting protocol for other bus systemsNo
Supporting protocol for Data-HighwayNo
Number of auxiliary contacts as normally open contact1
Number of command positions0
Rated operation current Ie8.5A
Degree of protection (IP)IP20
Rated control supply voltage Us at AC 50HZ230 - 230V
Number of auxiliary contacts as normally closed contact0
Supporting protocol for ModbusNo
Rated control supply voltage Us at DC0 - 0V
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Release classCLASS 10 A
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SafetyBUS pNo
Rated conditional short-circuit current, type 2, 230 V0A
Rated operation current at AC-3, 400 V9A
Type of motor starterDirect online starter (DOL)
Type of electrical connection of main circuitScrew connection
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
Temperature compensated overload protectionYes
Rated operation power at AC-3, 230 V, 3-phase2.2kW
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 2, 400 V100A
Voltage type for actuatingAC
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Ambient temperature, upper operating limit55°C
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPNo
With fuseNo
With short-circuit releaseYes
Supporting protocol for PROFIsafeNo
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Coordination class according to IEC 60947-4-3Class 1
Degree of protection (NEMA)Other
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-10-M9(230V50HZ)/BBA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Height

200mm

Rated operation power at AC-3, 400 V

4kW

Power consumption

1.4W

Width

45mm

With transformer

Depth

154mm

Supporting protocol for LON

Supporting protocol for SERCOS

Rail mounting possible

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for DeviceNet

External reset possible

Supporting protocol for SUCONET

Number of indicator lights

0

Suitable for emergency stop

Supporting protocol for ASI

Supporting protocol for CAN

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Overload release current setting

6.3 .. 10A

Supporting protocol for other bus systems

Supporting protocol for Data-Highway

Number of auxiliary contacts as normally open contact

1

Number of command positions

0

Rated operation current Ie

8.5A

Degree of protection (IP)

IP20

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Number of auxiliary contacts as normally closed contact

0

Supporting protocol for Modbus

Rated control supply voltage Us at DC

0 .. 0V

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Release class

CLASS 10 A

Supporting protocol for INTERBUS-Safety

Supporting protocol for SafetyBUS p

Rated conditional short-circuit current, type 2, 230 V

0A

Rated operation current at AC-3, 400 V

9A

Type of motor starter

Direct online starter (DOL)

Type of electrical connection of main circuit

Screw connection

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Temperature compensated overload protection

Rated operation power at AC-3, 230 V, 3-phase

2.2kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 2, 400 V

100A

Voltage type for actuating

AC

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet Safety

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Ambient temperature, upper operating limit

55°C

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

With fuse

With short-circuit release

Supporting protocol for PROFIsafe

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Coordination class according to IEC 60947-4-3

Class 1

Degree of protection (NEMA)

Other