Technical specifications

Width45mm
Number of command positions0
With transformerNo
Depth156mm
Rated operation power at AC-3, 400 V5.5kW
Height200mm
Power consumption2.1W
Number of auxiliary contacts as normally open contact1
Number of indicator lights0
Rated operation current Ie11.3A
Number of auxiliary contacts as normally closed contact0
Overload release current setting8 - 12A
Supporting protocol for TCP/IPNo
Suitable for emergency stopNo
Supporting protocol for PROFIBUSNo
Supporting protocol for LONNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUSNo
Supporting protocol for CANNo
Supporting protocol for ASINo
External reset possibleNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for DeviceNetNo
Rated control supply voltage Us at DC0 - 0V
Supporting protocol for SUCONETNo
Rated control supply voltage Us at AC 50HZ230 - 230V
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for other bus systemsNo
Degree of protection (IP)IP00
Supporting protocol for SERCOSNo
Rail mounting possibleNo
With fuseNo
Release classCLASS 10 A
Supporting protocol for DeviceNet SafetyNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for Foundation FieldbusNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPNo
Type of motor starterDirect online starter (DOL)
Voltage type for actuatingAC
With short-circuit releaseYes
Supporting protocol for SafetyBUS pNo
Rated power, 460 V, 60 Hz, 3-phase0kW
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET CBANo
Rated operation power at AC-3, 230 V, 3-phase3kW
Supporting protocol for PROFINET IONo
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 400 V50000A
Ambient temperature, upper operating limit55°C
Rated conditional short-circuit current, type 2, 230 V50000A
Temperature compensated overload protectionYes
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated operation current at AC-3, 400 V12A
Degree of protection (NEMA)Other
Coordination class according to IEC 60947-4-3Class 2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-12-M17(230V50HZ)/BBA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width

45mm

Number of command positions

0

With transformer

Depth

156mm

Rated operation power at AC-3, 400 V

5.5kW

Height

200mm

Power consumption

2.1W

Number of auxiliary contacts as normally open contact

1

Number of indicator lights

0

Rated operation current Ie

11.3A

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

8 .. 12A

Supporting protocol for TCP/IP

Suitable for emergency stop

Supporting protocol for PROFIBUS

Supporting protocol for LON

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for ASI

External reset possible

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for DeviceNet

Rated control supply voltage Us at DC

0 .. 0V

Supporting protocol for SUCONET

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Supporting protocol for INTERBUS-Safety

Supporting protocol for other bus systems

Degree of protection (IP)

IP00

Supporting protocol for SERCOS

Rail mounting possible

With fuse

Release class

CLASS 10 A

Supporting protocol for DeviceNet Safety

Type of electrical connection of main circuit

Screw connection

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

Type of motor starter

Direct online starter (DOL)

Voltage type for actuating

AC

With short-circuit release

Supporting protocol for SafetyBUS p

Rated power, 460 V, 60 Hz, 3-phase

0kW

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET CBA

Rated operation power at AC-3, 230 V, 3-phase

3kW

Supporting protocol for PROFINET IO

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 400 V

50000A

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 2, 230 V

50000A

Temperature compensated overload protection

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated operation current at AC-3, 400 V

12A

Degree of protection (NEMA)

Other

Coordination class according to IEC 60947-4-3

Class 2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.