Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
Voltage type for actuating
AC
With short-circuit release
Yes
Rated control supply voltage Us at AC 50HZ
230 - 230V
Rated operation power at AC-3, 400 V
7.5kW
Rated operation current at AC-3, 400 V
15A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Overload release current setting
10 - 16A
Rated operation power at AC-3, 230 V, 3-phase
4kW
Rated control supply voltage Us at DC
0 - 0V
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Power consumption
1.4W
Number of auxiliary contacts as normally closed contact
0
Rated operation current Ie
15.2A
Rated conditional short-circuit current, type 2, 230 V
0A
Number of auxiliary contacts as normally open contact
1
Rated conditional short-circuit current, type 2, 400 V
50A
Temperature compensated overload protection
Yes
Type of electrical connection of main circuit
Screw connection
Ambient temperature, upper operating limit
55°C
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rail mounting possible
No
Release class
CLASS 10 A
Number of command positions
0
With transformer
No
Number of indicator lights
0
Suitable for emergency stop
No
Coordination class according to IEC 60947-4-3
Class 1
With fuse
No
Rated control supply voltage Us at AC 60HZ
0 - 0V
Degree of protection (NEMA)
Other
Degree of protection (IP)
IP20
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for PROFIBUS
No
Supporting protocol for TCP/IP
No
Supporting protocol for ASI
No
Supporting protocol for CAN
No
Rated power, 575 V, 60 Hz, 3-phase
0kW
Supporting protocol for DeviceNet
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for INTERBUS
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for Data-Highway
No
External reset possible
No
Supporting protocol for SUCONET
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for Modbus
No
Supporting protocol for PROFIsafe
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Width
45mm
Height
200mm
Depth
154mm
Supporting protocol for EtherNet/IP
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SERCOS
No
From same serie
MSC-D-16-M15(230V50HZ)/BBA

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
Voltage type for actuating
AC
With short-circuit release
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Rated operation power at AC-3, 400 V
7.5kW
Rated operation current at AC-3, 400 V
15A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Overload release current setting
10 .. 16A
Rated operation power at AC-3, 230 V, 3-phase
4kW
Rated control supply voltage Us at DC
0 .. 0V
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Power consumption
1.4W
Number of auxiliary contacts as normally closed contact
0
Rated operation current Ie
15.2A
Rated conditional short-circuit current, type 2, 230 V
0A
Number of auxiliary contacts as normally open contact
1
Rated conditional short-circuit current, type 2, 400 V
50A
Temperature compensated overload protection
Type of electrical connection of main circuit
Screw connection
Ambient temperature, upper operating limit
55°C
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rail mounting possible
Release class
CLASS 10 A
Number of command positions
0
With transformer
Number of indicator lights
0
Suitable for emergency stop
Coordination class according to IEC 60947-4-3
Class 1
With fuse
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Degree of protection (NEMA)
Other
Degree of protection (IP)
IP20
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for PROFIBUS
Supporting protocol for TCP/IP
Supporting protocol for ASI
Supporting protocol for CAN
Rated power, 575 V, 60 Hz, 3-phase
0kW
Supporting protocol for DeviceNet
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for INTERBUS
Supporting protocol for PROFINET CBA
Supporting protocol for Data-Highway
External reset possible
Supporting protocol for SUCONET
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for Modbus
Supporting protocol for PROFIsafe
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Width
45mm
Height
200mm
Depth
154mm
Supporting protocol for EtherNet/IP
Supporting protocol for Foundation Fieldbus
Supporting protocol for SERCOS
From same serie