Aleta.hr
Main Product Image

MSC-D-16-M17(230V50HZ)/BBA

Code: 1957869

ManufacturerRAZNO
Catalog number102961
Type
EAN code4015081028009

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Rated control supply voltage Us at AC 50HZ

230 - 230V

With short-circuit release

Yes

Type of motor starter

Direct online starter (DOL)

Voltage type for actuating

AC

Rated operation power at AC-3, 400 V

7.5kW

Rated control supply voltage Us at DC

0 - 0V

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation current Ie

15.2A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated operation power at AC-3, 230 V, 3-phase

4kW

Rated control supply voltage Us at AC 60HZ

0 - 0V

Rated operation current at AC-3, 400 V

16A

Overload release current setting

10 - 16A

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated conditional short-circuit current, type 2, 400 V

50000A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

1

Temperature compensated overload protection

Yes

Power consumption

2.1W

Ambient temperature, upper operating limit

55°C

Type of electrical connection of main circuit

Screw connection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Release class

CLASS 10 A

Supporting protocol for PROFIBUS

No

Supporting protocol for TCP/IP

No

Supporting protocol for CAN

No

External reset possible

No

Degree of protection (NEMA)

Other

With fuse

No

Supporting protocol for DeviceNet

No

Rail mounting possible

No

Degree of protection (IP)

IP00

Number of command positions

0

Supporting protocol for Data-Highway

No

Coordination class according to IEC 60947-4-3

Class 2

With transformer

No

Number of indicator lights

0

Supporting protocol for Modbus

No

Supporting protocol for INTERBUS

No

Suitable for emergency stop

No

Supporting protocol for ASI

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for SafetyBUS p

No

Supporting protocol for other bus systems

No

Width

45mm

Height

200mm

Depth

156mm

Supporting protocol for PROFINET IO

No

Supporting protocol for SERCOS

No

Supporting protocol for LON

No

Supporting protocol for SUCONET

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for EtherNet/IP

No


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

MSC-D-16-M17(230V50HZ)/BBA

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Rated control supply voltage Us at AC 50HZ

230 .. 230V

With short-circuit release

Type of motor starter

Direct online starter (DOL)

Voltage type for actuating

AC

Rated operation power at AC-3, 400 V

7.5kW

Rated control supply voltage Us at DC

0 .. 0V

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation current Ie

15.2A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated operation power at AC-3, 230 V, 3-phase

4kW

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated operation current at AC-3, 400 V

16A

Overload release current setting

10 .. 16A

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated conditional short-circuit current, type 2, 400 V

50000A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

1

Temperature compensated overload protection

Power consumption

2.1W

Ambient temperature, upper operating limit

55°C

Type of electrical connection of main circuit

Screw connection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Release class

CLASS 10 A

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Supporting protocol for CAN

External reset possible

Degree of protection (NEMA)

Other

With fuse

Supporting protocol for DeviceNet

Rail mounting possible

Degree of protection (IP)

IP00

Number of command positions

0

Supporting protocol for Data-Highway

Coordination class according to IEC 60947-4-3

Class 2

With transformer

Number of indicator lights

0

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Suitable for emergency stop

Supporting protocol for ASI

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Width

45mm

Height

200mm

Depth

156mm

Supporting protocol for PROFINET IO

Supporting protocol for SERCOS

Supporting protocol for LON

Supporting protocol for SUCONET

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.