Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width45mm
Height200mm
Supporting protocol for CANNo
Number of command positions0
With transformerNo
Number of auxiliary contacts as normally open contact1
Power consumption2.1W
Rated operation power at AC-3, 400 V7.5kW
Rated operation current Ie15.2A
Supporting protocol for ASINo
Supporting protocol for TCP/IPNo
Supporting protocol for INTERBUSNo
Depth156mm
Overload release current setting10 - 16A
Number of auxiliary contacts as normally closed contact0
Supporting protocol for ModbusNo
Suitable for emergency stopNo
Supporting protocol for LONNo
Supporting protocol for PROFIBUSNo
Number of indicator lights0
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
External reset possibleNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
Rated control supply voltage Us at AC 50HZ230 - 230V
Rated control supply voltage Us at AC 60HZ0 - 0V
With short-circuit releaseYes
Rated control supply voltage Us at DC0 - 0V
Supporting protocol for AS-Interface Safety at WorkNo
Release classCLASS 10 A
Degree of protection (IP)IP00
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Type of electrical connection of main circuitScrew connection
Rail mounting possibleNo
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET IONo
With fuseNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for DeviceNet SafetyNo
Rated operation power at AC-3, 230 V, 3-phase4kW
Rated power, 575 V, 60 Hz, 3-phase0kW
Voltage type for actuatingAC
Type of motor starterDirect online starter (DOL)
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 400 V50000A
Rated operation current at AC-3, 400 V16A
Rated conditional short-circuit current, type 2, 230 V50000A
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Ambient temperature, upper operating limit55°C
Coordination class according to IEC 60947-4-3Class 2
Degree of protection (NEMA)Other
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-16-M17(230V50HZ)/BBA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width

45mm

Height

200mm

Supporting protocol for CAN

Number of command positions

0

With transformer

Number of auxiliary contacts as normally open contact

1

Power consumption

2.1W

Rated operation power at AC-3, 400 V

7.5kW

Rated operation current Ie

15.2A

Supporting protocol for ASI

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Depth

156mm

Overload release current setting

10 .. 16A

Number of auxiliary contacts as normally closed contact

0

Supporting protocol for Modbus

Suitable for emergency stop

Supporting protocol for LON

Supporting protocol for PROFIBUS

Number of indicator lights

0

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

External reset possible

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Rated control supply voltage Us at AC 60HZ

0 .. 0V

With short-circuit release

Rated control supply voltage Us at DC

0 .. 0V

Supporting protocol for AS-Interface Safety at Work

Release class

CLASS 10 A

Degree of protection (IP)

IP00

Supporting protocol for Foundation Fieldbus

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Type of electrical connection of main circuit

Screw connection

Rail mounting possible

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

With fuse

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for DeviceNet Safety

Rated operation power at AC-3, 230 V, 3-phase

4kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Voltage type for actuating

AC

Type of motor starter

Direct online starter (DOL)

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated operation current at AC-3, 400 V

16A

Rated conditional short-circuit current, type 2, 230 V

50000A

Temperature compensated overload protection

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Ambient temperature, upper operating limit

55°C

Coordination class according to IEC 60947-4-3

Class 2

Degree of protection (NEMA)

Other

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.