Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With short-circuit release
Yes
Rated control supply voltage Us at AC 50HZ
0 - 0V
Type of motor starter
Direct online starter (DOL)
Voltage type for actuating
DC
Rated operation power at AC-3, 230 V, 3-phase
0.04kW
Rated operation power at AC-3, 400 V
0.06kW
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation current Ie
0.21A
Rated operation current at AC-3, 400 V
0.25A
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Number of auxiliary contacts as normally open contact
1
Rated conditional short-circuit current, type 2, 400 V
50000A
Overload release current setting
0.16 - 0.25A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Ambient temperature, upper operating limit
55°C
Number of auxiliary contacts as normally closed contact
0
Power consumption
2.6W
Release class
CLASS 10 A
Type of electrical connection of main circuit
Screw connection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Number of command positions
0
With transformer
No
Coordination class according to IEC 60947-4-3
Class 2
Rail mounting possible
No
Suitable for emergency stop
No
External reset possible
No
Temperature compensated overload protection
Yes
Number of indicator lights
0
Degree of protection (IP)
IP20
Degree of protection (NEMA)
Other
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for TCP/IP
No
Supporting protocol for Modbus
No
Rated control supply voltage Us at DC
24 - 24V
Supporting protocol for SUCONET
No
Supporting protocol for DeviceNet
No
Supporting protocol for Data-Highway
No
With fuse
No
Supporting protocol for LON
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFINET IO
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Width
45mm
Height
170mm
Depth
76mm
From same serie
MSC-DM-0,25-M7(24VDC)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With short-circuit release
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Type of motor starter
Direct online starter (DOL)
Voltage type for actuating
DC
Rated operation power at AC-3, 230 V, 3-phase
0.04kW
Rated operation power at AC-3, 400 V
0.06kW
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation current Ie
0.21A
Rated operation current at AC-3, 400 V
0.25A
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Number of auxiliary contacts as normally open contact
1
Rated conditional short-circuit current, type 2, 400 V
50000A
Overload release current setting
0.16 .. 0.25A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Ambient temperature, upper operating limit
55°C
Number of auxiliary contacts as normally closed contact
0
Power consumption
2.6W
Release class
CLASS 10 A
Type of electrical connection of main circuit
Screw connection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Number of command positions
0
With transformer
Coordination class according to IEC 60947-4-3
Class 2
Rail mounting possible
Suitable for emergency stop
External reset possible
Temperature compensated overload protection
Number of indicator lights
0
Degree of protection (IP)
IP20
Degree of protection (NEMA)
Other
Supporting protocol for PROFIBUS
Supporting protocol for CAN
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for TCP/IP
Supporting protocol for Modbus
Rated control supply voltage Us at DC
24 .. 24V
Supporting protocol for SUCONET
Supporting protocol for DeviceNet
Supporting protocol for Data-Highway
With fuse
Supporting protocol for LON
Supporting protocol for PROFINET CBA
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFINET IO
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Width
45mm
Height
170mm
Depth
76mm
From same serie