Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-DM-0,4-M7(230V50HZ)

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With transformer
Power consumption
1.4W
Width
45mm
Depth
76mm
Height
170mm
Supporting protocol for TCP/IP
Number of indicator lights
0
Supporting protocol for LON
Supporting protocol for CAN
Rated operation current Ie
0.31A
Supporting protocol for Data-Highway
Number of auxiliary contacts as normally open contact
1
Number of auxiliary contacts as normally closed contact
0
Suitable for emergency stop
Supporting protocol for ASI
Overload release current setting
0.25 .. 0.4A
Supporting protocol for DeviceNet
Supporting protocol for PROFIBUS
Supporting protocol for Modbus
Supporting protocol for INTERBUS
Rated operation power at AC-3, 400 V
0.09kW
Number of command positions
0
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Rated control supply voltage Us at DC
0 .. 0V
Rail mounting possible
Supporting protocol for other bus systems
Supporting protocol for SUCONET
Degree of protection (IP)
IP20
Rated control supply voltage Us at AC 60HZ
0 .. 0V
External reset possible
Supporting protocol for SERCOS
Type of electrical connection of main circuit
Screw connection
Supporting protocol for PROFINET IO
Supporting protocol for Foundation Fieldbus
With fuse
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for AS-Interface Safety at Work
With short-circuit release
Supporting protocol for PROFINET CBA
Release class
CLASS 10 A
Supporting protocol for DeviceNet Safety
Supporting protocol for EtherNet/IP
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Rated operation current at AC-3, 400 V
0.4A
Ambient temperature, upper operating limit
55°C
Voltage type for actuating
AC
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Type of motor starter
Direct online starter (DOL)
Rated operation power at AC-3, 230 V, 3-phase
0.06kW
Supporting protocol for SafetyBUS p
Rated conditional short-circuit current, type 2, 400 V
50000A
Temperature compensated overload protection
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Degree of protection (NEMA)
Other
Coordination class according to IEC 60947-4-3
Class 2
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A