Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With transformerNo
Power consumption1.4W
Width45mm
Depth76mm
Height170mm
Supporting protocol for TCP/IPNo
Number of indicator lights0
Supporting protocol for LONNo
Supporting protocol for CANNo
Rated operation current Ie0.31A
Supporting protocol for Data-HighwayNo
Number of auxiliary contacts as normally open contact1
Number of auxiliary contacts as normally closed contact0
Suitable for emergency stopNo
Supporting protocol for ASINo
Overload release current setting0.25 - 0.4A
Supporting protocol for DeviceNetNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ModbusNo
Supporting protocol for INTERBUSNo
Rated operation power at AC-3, 400 V0.09kW
Number of command positions0
Rated control supply voltage Us at AC 50HZ230 - 230V
Rated control supply voltage Us at DC0 - 0V
Rail mounting possibleNo
Supporting protocol for other bus systemsNo
Supporting protocol for SUCONETNo
Degree of protection (IP)IP20
Rated control supply voltage Us at AC 60HZ0 - 0V
External reset possibleNo
Supporting protocol for SERCOSNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
With fuseNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
With short-circuit releaseYes
Supporting protocol for PROFINET CBANo
Release classCLASS 10 A
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Rated operation current at AC-3, 400 V0.4A
Ambient temperature, upper operating limit55°C
Voltage type for actuatingAC
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated power, 575 V, 60 Hz, 3-phase0kW
Type of motor starterDirect online starter (DOL)
Rated operation power at AC-3, 230 V, 3-phase0.06kW
Supporting protocol for SafetyBUS pNo
Rated conditional short-circuit current, type 2, 400 V50000A
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 2, 230 V50000A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Degree of protection (NEMA)Other
Coordination class according to IEC 60947-4-3Class 2
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DM-0,4-M7(230V50HZ)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With transformer

Power consumption

1.4W

Width

45mm

Depth

76mm

Height

170mm

Supporting protocol for TCP/IP

Number of indicator lights

0

Supporting protocol for LON

Supporting protocol for CAN

Rated operation current Ie

0.31A

Supporting protocol for Data-Highway

Number of auxiliary contacts as normally open contact

1

Number of auxiliary contacts as normally closed contact

0

Suitable for emergency stop

Supporting protocol for ASI

Overload release current setting

0.25 .. 0.4A

Supporting protocol for DeviceNet

Supporting protocol for PROFIBUS

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Rated operation power at AC-3, 400 V

0.09kW

Number of command positions

0

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Rated control supply voltage Us at DC

0 .. 0V

Rail mounting possible

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Degree of protection (IP)

IP20

Rated control supply voltage Us at AC 60HZ

0 .. 0V

External reset possible

Supporting protocol for SERCOS

Type of electrical connection of main circuit

Screw connection

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

With fuse

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for AS-Interface Safety at Work

With short-circuit release

Supporting protocol for PROFINET CBA

Release class

CLASS 10 A

Supporting protocol for DeviceNet Safety

Supporting protocol for EtherNet/IP

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Rated operation current at AC-3, 400 V

0.4A

Ambient temperature, upper operating limit

55°C

Voltage type for actuating

AC

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Type of motor starter

Direct online starter (DOL)

Rated operation power at AC-3, 230 V, 3-phase

0.06kW

Supporting protocol for SafetyBUS p

Rated conditional short-circuit current, type 2, 400 V

50000A

Temperature compensated overload protection

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Degree of protection (NEMA)

Other

Coordination class according to IEC 60947-4-3

Class 2

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.