Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Depth76mm
Width45mm
Number of command positions0
Rated operation power at AC-3, 400 V0.55kW
With transformerNo
Power consumption1.4W
Height170mm
Number of indicator lights0
Supporting protocol for INTERBUSNo
Supporting protocol for LONNo
Supporting protocol for SUCONETNo
Number of auxiliary contacts as normally closed contact0
Supporting protocol for DeviceNetNo
Suitable for emergency stopNo
Number of auxiliary contacts as normally open contact1
Supporting protocol for TCP/IPNo
Rated operation current Ie1.5A
Overload release current setting1 - 1.6A
Supporting protocol for other bus systemsNo
Supporting protocol for CANNo
External reset possibleNo
Rail mounting possibleNo
Supporting protocol for ModbusNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Supporting protocol for SERCOSNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Degree of protection (IP)IP20
Rated control supply voltage Us at AC 50HZ230 - 230V
Supporting protocol for INTERBUS-SafetyNo
Rated control supply voltage Us at DC0 - 0V
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
With short-circuit releaseYes
Supporting protocol for AS-Interface Safety at WorkNo
Rated power, 575 V, 60 Hz, 3-phase0kW
Type of motor starterDirect online starter (DOL)
Release classCLASS 10 A
Supporting protocol for PROFIsafeNo
Supporting protocol for EtherNet/IPNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for SafetyBUS pNo
With fuseNo
Supporting protocol for PROFINET IONo
Type of electrical connection of main circuitScrew connection
Voltage type for actuatingAC
Rated operation power at AC-3, 230 V, 3-phase0.25kW
Rated power, 460 V, 60 Hz, 3-phase0kW
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 2, 400 V50000A
Rated operation current at AC-3, 400 V1.6A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Ambient temperature, upper operating limit55°C
Rated conditional short-circuit current, type 2, 230 V50000A
Coordination class according to IEC 60947-4-3Class 2
Degree of protection (NEMA)Other
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DM-1,6-M7(230V50HZ)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Depth

76mm

Width

45mm

Number of command positions

0

Rated operation power at AC-3, 400 V

0.55kW

With transformer

Power consumption

1.4W

Height

170mm

Number of indicator lights

0

Supporting protocol for INTERBUS

Supporting protocol for LON

Supporting protocol for SUCONET

Number of auxiliary contacts as normally closed contact

0

Supporting protocol for DeviceNet

Suitable for emergency stop

Number of auxiliary contacts as normally open contact

1

Supporting protocol for TCP/IP

Rated operation current Ie

1.5A

Overload release current setting

1 .. 1.6A

Supporting protocol for other bus systems

Supporting protocol for CAN

External reset possible

Rail mounting possible

Supporting protocol for Modbus

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Supporting protocol for SERCOS

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Degree of protection (IP)

IP20

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Supporting protocol for INTERBUS-Safety

Rated control supply voltage Us at DC

0 .. 0V

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

With short-circuit release

Supporting protocol for AS-Interface Safety at Work

Rated power, 575 V, 60 Hz, 3-phase

0kW

Type of motor starter

Direct online starter (DOL)

Release class

CLASS 10 A

Supporting protocol for PROFIsafe

Supporting protocol for EtherNet/IP

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for SafetyBUS p

With fuse

Supporting protocol for PROFINET IO

Type of electrical connection of main circuit

Screw connection

Voltage type for actuating

AC

Rated operation power at AC-3, 230 V, 3-phase

0.25kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Temperature compensated overload protection

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated operation current at AC-3, 400 V

1.6A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 2, 230 V

50000A

Coordination class according to IEC 60947-4-3

Class 2

Degree of protection (NEMA)

Other

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.