Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-DM-1,6-M7(230V50HZ)

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Depth
76mm
Width
45mm
Number of command positions
0
Rated operation power at AC-3, 400 V
0.55kW
With transformer
Power consumption
1.4W
Height
170mm
Number of indicator lights
0
Supporting protocol for INTERBUS
Supporting protocol for LON
Supporting protocol for SUCONET
Number of auxiliary contacts as normally closed contact
0
Supporting protocol for DeviceNet
Suitable for emergency stop
Number of auxiliary contacts as normally open contact
1
Supporting protocol for TCP/IP
Rated operation current Ie
1.5A
Overload release current setting
1 .. 1.6A
Supporting protocol for other bus systems
Supporting protocol for CAN
External reset possible
Rail mounting possible
Supporting protocol for Modbus
Supporting protocol for ASI
Supporting protocol for PROFIBUS
Supporting protocol for SERCOS
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Degree of protection (IP)
IP20
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Supporting protocol for INTERBUS-Safety
Rated control supply voltage Us at DC
0 .. 0V
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet Safety
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFINET CBA
With short-circuit release
Supporting protocol for AS-Interface Safety at Work
Rated power, 575 V, 60 Hz, 3-phase
0kW
Type of motor starter
Direct online starter (DOL)
Release class
CLASS 10 A
Supporting protocol for PROFIsafe
Supporting protocol for EtherNet/IP
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for SafetyBUS p
With fuse
Supporting protocol for PROFINET IO
Type of electrical connection of main circuit
Screw connection
Voltage type for actuating
AC
Rated operation power at AC-3, 230 V, 3-phase
0.25kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Temperature compensated overload protection
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated operation current at AC-3, 400 V
1.6A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Ambient temperature, upper operating limit
55°C
Rated conditional short-circuit current, type 2, 230 V
50000A
Coordination class according to IEC 60947-4-3
Class 2
Degree of protection (NEMA)
Other