Technical specifications

Width45mm
Number of auxiliary contacts as normally closed contact0
Suitable for emergency stopNo
Number of command positions0
Number of auxiliary contacts as normally open contact1
Supporting protocol for CANNo
Supporting protocol for other bus systemsNo
Supporting protocol for TCP/IPNo
Depth97.5mm
Height197mm
Overload release current setting6.3 - 10A
Supporting protocol for INTERBUSNo
Supporting protocol for Data-HighwayNo
Rated operation current Ie8.5A
Supporting protocol for SUCONETNo
Number of indicator lights0
Supporting protocol for ModbusNo
Rated operation power at AC-3, 400 V4kW
Power consumption2.1W
Supporting protocol for PROFIBUSNo
With transformerNo
Supporting protocol for DeviceNetNo
External reset possibleNo
Supporting protocol for ASINo
Supporting protocol for LONNo
Rail mounting possibleNo
Supporting protocol for PROFINET IONo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Supporting protocol for EtherNet/IPNo
Rated control supply voltage Us at AC 50HZ230 - 230V
Rated power, 460 V, 60 Hz, 3-phase0kW
Supporting protocol for PROFINET CBANo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for Foundation FieldbusNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for AS-Interface Safety at WorkNo
With short-circuit releaseYes
Supporting protocol for DeviceNet SafetyNo
Rated control supply voltage Us at DC0 - 0V
With fuseNo
Degree of protection (IP)IP20
Voltage type for actuatingAC
Release classCLASS 10 A
Type of motor starterDirect online starter (DOL)
Supporting protocol for SERCOSNo
Rated operation power at AC-3, 230 V, 3-phase2.2kW
Type of electrical connection for auxiliary- and control current circuitScrew connection
Type of electrical connection of main circuitScrew connection
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated operation current at AC-3, 400 V10A
Coordination class according to IEC 60947-4-3Class 2
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 2, 230 V50000A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 400 V50000A
Degree of protection (NEMA)Other
Ambient temperature, upper operating limit55°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DM-10-M17(230V50HZ)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width

45mm

Number of auxiliary contacts as normally closed contact

0

Suitable for emergency stop

Number of command positions

0

Number of auxiliary contacts as normally open contact

1

Supporting protocol for CAN

Supporting protocol for other bus systems

Supporting protocol for TCP/IP

Depth

97.5mm

Height

197mm

Overload release current setting

6.3 .. 10A

Supporting protocol for INTERBUS

Supporting protocol for Data-Highway

Rated operation current Ie

8.5A

Supporting protocol for SUCONET

Number of indicator lights

0

Supporting protocol for Modbus

Rated operation power at AC-3, 400 V

4kW

Power consumption

2.1W

Supporting protocol for PROFIBUS

With transformer

Supporting protocol for DeviceNet

External reset possible

Supporting protocol for ASI

Supporting protocol for LON

Rail mounting possible

Supporting protocol for PROFINET IO

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Supporting protocol for EtherNet/IP

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Rated power, 460 V, 60 Hz, 3-phase

0kW

Supporting protocol for PROFINET CBA

Supporting protocol for INTERBUS-Safety

Supporting protocol for Foundation Fieldbus

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for AS-Interface Safety at Work

With short-circuit release

Supporting protocol for DeviceNet Safety

Rated control supply voltage Us at DC

0 .. 0V

With fuse

Degree of protection (IP)

IP20

Voltage type for actuating

AC

Release class

CLASS 10 A

Type of motor starter

Direct online starter (DOL)

Supporting protocol for SERCOS

Rated operation power at AC-3, 230 V, 3-phase

2.2kW

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Type of electrical connection of main circuit

Screw connection

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

10A

Coordination class according to IEC 60947-4-3

Class 2

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Temperature compensated overload protection

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 400 V

50000A

Degree of protection (NEMA)

Other

Ambient temperature, upper operating limit

55°C