Technical specifications
Width
45mm
Height
197mm
Depth
97.5mm
Power consumption
0.9W
With transformer
Rated operation current Ie
8.5A
Supporting protocol for LON
Supporting protocol for CAN
Suitable for emergency stop
Supporting protocol for INTERBUS
Number of command positions
0
Supporting protocol for ASI
Supporting protocol for Data-Highway
Supporting protocol for SUCONET
Supporting protocol for PROFIBUS
Number of auxiliary contacts as normally open contact
1
Supporting protocol for Modbus
Supporting protocol for other bus systems
Supporting protocol for DeviceNet
Number of indicator lights
0
Number of auxiliary contacts as normally closed contact
0
Supporting protocol for TCP/IP
Overload release current setting
6.3 .. 10A
Rated operation power at AC-3, 400 V
4kW
External reset possible
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Rail mounting possible
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated control supply voltage Us at DC
24 .. 24V
Degree of protection (IP)
IP20
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for Foundation Fieldbus
Rated power, 575 V, 60 Hz, 3-phase
0kW
Supporting protocol for INTERBUS-Safety
With fuse
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Voltage type for actuating
DC
Supporting protocol for PROFIsafe
Supporting protocol for DeviceNet Safety
Type of motor starter
Direct online starter (DOL)
Supporting protocol for PROFINET CBA
Supporting protocol for PROFINET IO
Release class
CLASS 10 A
Rated operation power at AC-3, 230 V, 3-phase
2.2kW
With short-circuit release
Rated power, 460 V, 60 Hz, 3-phase
0kW
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Type of electrical connection of main circuit
Screw connection
Supporting protocol for SafetyBUS p
Rated operation current at AC-3, 400 V
10A
Ambient temperature, upper operating limit
55°C
Temperature compensated overload protection
Rated conditional short-circuit current, type 2, 400 V
50000A
Degree of protection (NEMA)
Other
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated conditional short-circuit current, type 2, 230 V
50000A
Coordination class according to IEC 60947-4-3
Class 2
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A