Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width45mm
Height197mm
Depth97.5mm
Power consumption0.9W
With transformerNo
Rated operation current Ie8.5A
Supporting protocol for LONNo
Supporting protocol for CANNo
Suitable for emergency stopNo
Supporting protocol for INTERBUSNo
Number of command positions0
Supporting protocol for ASINo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Supporting protocol for PROFIBUSNo
Number of auxiliary contacts as normally open contact1
Supporting protocol for ModbusNo
Supporting protocol for other bus systemsNo
Supporting protocol for DeviceNetNo
Number of indicator lights0
Number of auxiliary contacts as normally closed contact0
Supporting protocol for TCP/IPNo
Overload release current setting6.3 - 10A
Rated operation power at AC-3, 400 V4kW
External reset possibleNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Rail mounting possibleNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated control supply voltage Us at DC24 - 24V
Degree of protection (IP)IP20
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
Rated power, 575 V, 60 Hz, 3-phase0kW
Supporting protocol for INTERBUS-SafetyNo
With fuseNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Voltage type for actuatingDC
Supporting protocol for PROFIsafeNo
Supporting protocol for DeviceNet SafetyNo
Type of motor starterDirect online starter (DOL)
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Release classCLASS 10 A
Rated operation power at AC-3, 230 V, 3-phase2.2kW
With short-circuit releaseYes
Rated power, 460 V, 60 Hz, 3-phase0kW
Supporting protocol for SERCOSNo
Supporting protocol for EtherNet/IPNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for SafetyBUS pNo
Rated operation current at AC-3, 400 V10A
Ambient temperature, upper operating limit55°C
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 2, 400 V50000A
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 2, 230 V50000A
Coordination class according to IEC 60947-4-3Class 2
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DM-10-M17(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width

45mm

Height

197mm

Depth

97.5mm

Power consumption

0.9W

With transformer

Rated operation current Ie

8.5A

Supporting protocol for LON

Supporting protocol for CAN

Suitable for emergency stop

Supporting protocol for INTERBUS

Number of command positions

0

Supporting protocol for ASI

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for PROFIBUS

Number of auxiliary contacts as normally open contact

1

Supporting protocol for Modbus

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Number of indicator lights

0

Number of auxiliary contacts as normally closed contact

0

Supporting protocol for TCP/IP

Overload release current setting

6.3 .. 10A

Rated operation power at AC-3, 400 V

4kW

External reset possible

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rail mounting possible

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated control supply voltage Us at DC

24 .. 24V

Degree of protection (IP)

IP20

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Rated power, 575 V, 60 Hz, 3-phase

0kW

Supporting protocol for INTERBUS-Safety

With fuse

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Voltage type for actuating

DC

Supporting protocol for PROFIsafe

Supporting protocol for DeviceNet Safety

Type of motor starter

Direct online starter (DOL)

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Release class

CLASS 10 A

Rated operation power at AC-3, 230 V, 3-phase

2.2kW

With short-circuit release

Rated power, 460 V, 60 Hz, 3-phase

0kW

Supporting protocol for SERCOS

Supporting protocol for EtherNet/IP

Type of electrical connection of main circuit

Screw connection

Supporting protocol for SafetyBUS p

Rated operation current at AC-3, 400 V

10A

Ambient temperature, upper operating limit

55°C

Temperature compensated overload protection

Rated conditional short-circuit current, type 2, 400 V

50000A

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 2, 230 V

50000A

Coordination class according to IEC 60947-4-3

Class 2

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.