Technical specifications
MSC-DM-10-M7(230V50HZ)

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Supporting protocol for LON
With transformer
Height
170mm
Rated operation current Ie
6.6A
Power consumption
1.4W
Number of auxiliary contacts as normally closed contact
0
Width
45mm
Number of auxiliary contacts as normally open contact
1
Rated operation power at AC-3, 400 V
3kW
Overload release current setting
6.3 .. 10A
Depth
76mm
Number of command positions
0
Number of indicator lights
0
Suitable for emergency stop
Supporting protocol for ASI
Supporting protocol for TCP/IP
Supporting protocol for CAN
Supporting protocol for INTERBUS
External reset possible
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated control supply voltage Us at DC
0 .. 0V
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIBUS
Degree of protection (IP)
IP20
Release class
CLASS 10 A
Rail mounting possible
Supporting protocol for other bus systems
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Supporting protocol for DeviceNet
Supporting protocol for Modbus
Supporting protocol for SERCOS
Supporting protocol for SUCONET
Supporting protocol for Data-Highway
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for EtherNet/IP
Type of electrical connection for auxiliary- and control current circuit
Screw connection
With fuse
Type of electrical connection of main circuit
Screw connection
Supporting protocol for Foundation Fieldbus
Supporting protocol for DeviceNet Safety
With short-circuit release
Type of motor starter
Direct online starter (DOL)
Supporting protocol for PROFINET IO
Supporting protocol for PROFIsafe
Supporting protocol for PROFINET CBA
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Voltage type for actuating
AC
Rated power, 460 V, 60 Hz, 3-phase
0kW
Temperature compensated overload protection
Rated conditional short-circuit current, type 2, 400 V
0A
Rated conditional short-circuit current, type 2, 230 V
0A
Supporting protocol for SafetyBUS p
Coordination class according to IEC 60947-4-3
Class 1
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation current at AC-3, 400 V
7A
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Ambient temperature, upper operating limit
55°C
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Degree of protection (NEMA)
Other