Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With short-circuit release
Yes
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated control supply voltage Us at AC 50HZ
0 - 0V
Voltage type for actuating
DC
Rated control supply voltage Us at DC
24 - 24V
Rated operation power at AC-3, 400 V
3kW
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation current Ie
6.6A
Rated operation current at AC-3, 400 V
7A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Overload release current setting
6.3 - 10A
Rated conditional short-circuit current, type 2, 230 V
0A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Number of auxiliary contacts as normally open contact
1
Rated conditional short-circuit current, type 2, 400 V
0A
Power consumption
2.6W
Number of auxiliary contacts as normally closed contact
0
Temperature compensated overload protection
Yes
Type of electrical connection of main circuit
Screw connection
Ambient temperature, upper operating limit
55°C
Release class
CLASS 10 A
Number of command positions
0
With transformer
No
Coordination class according to IEC 60947-4-3
Class 1
Suitable for emergency stop
No
Number of indicator lights
0
Degree of protection (NEMA)
Other
Degree of protection (IP)
IP20
Supporting protocol for TCP/IP
No
External reset possible
No
With fuse
No
Supporting protocol for PROFIBUS
No
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rail mounting possible
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
No
Width
45mm
Height
170mm
Depth
76mm
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for DeviceNet
No
Supporting protocol for CAN
No
Supporting protocol for Modbus
No
Supporting protocol for SUCONET
No
Supporting protocol for Data-Highway
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for PROFINET CBA
No
From same serie
MSC-DM-10-M7(24VDC)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With short-circuit release
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Voltage type for actuating
DC
Rated control supply voltage Us at DC
24 .. 24V
Rated operation power at AC-3, 400 V
3kW
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation current Ie
6.6A
Rated operation current at AC-3, 400 V
7A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Overload release current setting
6.3 .. 10A
Rated conditional short-circuit current, type 2, 230 V
0A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Number of auxiliary contacts as normally open contact
1
Rated conditional short-circuit current, type 2, 400 V
0A
Power consumption
2.6W
Number of auxiliary contacts as normally closed contact
0
Temperature compensated overload protection
Type of electrical connection of main circuit
Screw connection
Ambient temperature, upper operating limit
55°C
Release class
CLASS 10 A
Number of command positions
0
With transformer
Coordination class according to IEC 60947-4-3
Class 1
Suitable for emergency stop
Number of indicator lights
0
Degree of protection (NEMA)
Other
Degree of protection (IP)
IP20
Supporting protocol for TCP/IP
External reset possible
With fuse
Supporting protocol for PROFIBUS
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rail mounting possible
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Width
45mm
Height
170mm
Depth
76mm
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for DeviceNet
Supporting protocol for CAN
Supporting protocol for Modbus
Supporting protocol for SUCONET
Supporting protocol for Data-Highway
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for Foundation Fieldbus
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET CBA
From same serie