Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Depth76mm
Number of auxiliary contacts as normally open contact1
Number of auxiliary contacts as normally closed contact0
Suitable for emergency stopNo
Power consumption1.4W
Height170mm
Number of command positions0
Width45mm
With transformerNo
Rated operation power at AC-3, 400 V4kW
Overload release current setting6.3 - 10A
Number of indicator lights0
Rated operation current Ie8.5A
Supporting protocol for LONNo
Supporting protocol for ASINo
Supporting protocol for CANNo
Rated control supply voltage Us at AC 50HZ230 - 230V
Supporting protocol for TCP/IPNo
Supporting protocol for Data-HighwayNo
External reset possibleNo
Rated control supply voltage Us at DC0 - 0V
Supporting protocol for INTERBUS-SafetyNo
Release classCLASS 10 A
Supporting protocol for PROFIBUSNo
Supporting protocol for DeviceNetNo
Rail mounting possibleNo
Supporting protocol for INTERBUSNo
Supporting protocol for SERCOSNo
With short-circuit releaseYes
Supporting protocol for other bus systemsNo
Supporting protocol for ModbusNo
Supporting protocol for SUCONETNo
Degree of protection (IP)IP20
Rated control supply voltage Us at AC 60HZ0 - 0V
With fuseNo
Supporting protocol for AS-Interface Safety at WorkNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Type of electrical connection of main circuitScrew connection
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo
Temperature compensated overload protectionYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPNo
Rated conditional short-circuit current, type 2, 400 V0A
Rated conditional short-circuit current, type 2, 230 V0A
Rated power, 575 V, 60 Hz, 3-phase0kW
Supporting protocol for SafetyBUS pNo
Rated operation power at AC-3, 230 V, 3-phase2.2kW
Rated operation current at AC-3, 400 V9A
Voltage type for actuatingAC
Ambient temperature, upper operating limit55°C
Type of motor starterDirect online starter (DOL)
Coordination class according to IEC 60947-4-3Class 1
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated power, 460 V, 60 Hz, 3-phase0kW
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DM-10-M9(230V50HZ)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Depth

76mm

Number of auxiliary contacts as normally open contact

1

Number of auxiliary contacts as normally closed contact

0

Suitable for emergency stop

Power consumption

1.4W

Height

170mm

Number of command positions

0

Width

45mm

With transformer

Rated operation power at AC-3, 400 V

4kW

Overload release current setting

6.3 .. 10A

Number of indicator lights

0

Rated operation current Ie

8.5A

Supporting protocol for LON

Supporting protocol for ASI

Supporting protocol for CAN

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Supporting protocol for TCP/IP

Supporting protocol for Data-Highway

External reset possible

Rated control supply voltage Us at DC

0 .. 0V

Supporting protocol for INTERBUS-Safety

Release class

CLASS 10 A

Supporting protocol for PROFIBUS

Supporting protocol for DeviceNet

Rail mounting possible

Supporting protocol for INTERBUS

Supporting protocol for SERCOS

With short-circuit release

Supporting protocol for other bus systems

Supporting protocol for Modbus

Supporting protocol for SUCONET

Degree of protection (IP)

IP20

Rated control supply voltage Us at AC 60HZ

0 .. 0V

With fuse

Supporting protocol for AS-Interface Safety at Work

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Type of electrical connection of main circuit

Screw connection

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Temperature compensated overload protection

Supporting protocol for DeviceNet Safety

Supporting protocol for EtherNet/IP

Rated conditional short-circuit current, type 2, 400 V

0A

Rated conditional short-circuit current, type 2, 230 V

0A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Supporting protocol for SafetyBUS p

Rated operation power at AC-3, 230 V, 3-phase

2.2kW

Rated operation current at AC-3, 400 V

9A

Voltage type for actuating

AC

Ambient temperature, upper operating limit

55°C

Type of motor starter

Direct online starter (DOL)

Coordination class according to IEC 60947-4-3

Class 1

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated power, 460 V, 60 Hz, 3-phase

0kW

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.