Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Height170mm
Width45mm
Depth76mm
With transformerNo
Power consumption2.6W
Rated operation power at AC-3, 400 V4kW
Number of auxiliary contacts as normally open contact1
Suitable for emergency stopNo
Rated operation current Ie8.5A
Supporting protocol for TCP/IPNo
Number of command positions0
Number of indicator lights0
Overload release current setting6.3 - 10A
Number of auxiliary contacts as normally closed contact0
Supporting protocol for LONNo
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusNo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for ASINo
External reset possibleNo
Rail mounting possibleNo
Supporting protocol for other bus systemsNo
Supporting protocol for DeviceNetNo
Degree of protection (IP)IP20
Rated control supply voltage Us at DC24 - 24V
Rated control supply voltage Us at AC 50HZ0 - 0V
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for SERCOSNo
Release classCLASS 10 A
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for DeviceNet SafetyNo
With fuseNo
Supporting protocol for AS-Interface Safety at WorkNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for INTERBUS-SafetyNo
With short-circuit releaseYes
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET IONo
Rated operation power at AC-3, 230 V, 3-phase2.2kW
Voltage type for actuatingDC
Rated power, 460 V, 60 Hz, 3-phase0kW
Supporting protocol for SafetyBUS pNo
Rated operation current at AC-3, 400 V9A
Rated power, 575 V, 60 Hz, 3-phase0kW
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Type of motor starterDirect online starter (DOL)
Supporting protocol for PROFIsafeNo
Temperature compensated overload protectionYes
Ambient temperature, upper operating limit55°C
Rated conditional short-circuit current, type 2, 230 V0A
Rated conditional short-circuit current, type 2, 400 V0A
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Coordination class according to IEC 60947-4-3Class 1
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DM-10-M9(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Height

170mm

Width

45mm

Depth

76mm

With transformer

Power consumption

2.6W

Rated operation power at AC-3, 400 V

4kW

Number of auxiliary contacts as normally open contact

1

Suitable for emergency stop

Rated operation current Ie

8.5A

Supporting protocol for TCP/IP

Number of command positions

0

Number of indicator lights

0

Overload release current setting

6.3 .. 10A

Number of auxiliary contacts as normally closed contact

0

Supporting protocol for LON

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for SUCONET

Supporting protocol for ASI

External reset possible

Rail mounting possible

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Degree of protection (IP)

IP20

Rated control supply voltage Us at DC

24 .. 24V

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for SERCOS

Release class

CLASS 10 A

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for DeviceNet Safety

With fuse

Supporting protocol for AS-Interface Safety at Work

Type of electrical connection of main circuit

Screw connection

Supporting protocol for INTERBUS-Safety

With short-circuit release

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Rated operation power at AC-3, 230 V, 3-phase

2.2kW

Voltage type for actuating

DC

Rated power, 460 V, 60 Hz, 3-phase

0kW

Supporting protocol for SafetyBUS p

Rated operation current at AC-3, 400 V

9A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Type of motor starter

Direct online starter (DOL)

Supporting protocol for PROFIsafe

Temperature compensated overload protection

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 2, 230 V

0A

Rated conditional short-circuit current, type 2, 400 V

0A

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Coordination class according to IEC 60947-4-3

Class 1

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.