Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With transformerNo
Height170mm
Depth76mm
Power consumption1.4W
Width45mm
Rated operation power at AC-3, 400 V5.5kW
Overload release current setting8 - 12A
Number of auxiliary contacts as normally open contact1
Rated operation current Ie11.3A
Rated control supply voltage Us at AC 50HZ230 - 230V
Number of indicator lights0
Supporting protocol for ASINo
Supporting protocol for CANNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for LONNo
External reset possibleNo
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP20
Supporting protocol for PROFIBUSNo
Suitable for emergency stopNo
Supporting protocol for ModbusNo
Supporting protocol for DeviceNetNo
Number of command positions0
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUSNo
Rated control supply voltage Us at DC0 - 0V
Supporting protocol for other bus systemsNo
Supporting protocol for Data-HighwayNo
Rail mounting possibleNo
Supporting protocol for TCP/IPNo
Release classCLASS 10 A
Type of electrical connection of main circuitScrew connection
With fuseNo
Rated operation power at AC-3, 230 V, 3-phase3kW
Voltage type for actuatingAC
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Supporting protocol for PROFIsafeNo
Rated power, 460 V, 60 Hz, 3-phase0kW
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
With short-circuit releaseYes
Supporting protocol for DeviceNet SafetyNo
Rated power, 575 V, 60 Hz, 3-phase0kW
Supporting protocol for PROFINET CBANo
Type of motor starterDirect online starter (DOL)
Supporting protocol for PROFINET IONo
Supporting protocol for SafetyBUS pNo
Rated conditional short-circuit current, type 2, 230 V0A
Ambient temperature, upper operating limit55°C
Temperature compensated overload protectionYes
Rated operation current at AC-3, 400 V12A
Rated conditional short-circuit current, type 2, 400 V0A
Coordination class according to IEC 60947-4-3Class 1
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Degree of protection (NEMA)Other
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DM-12-M12(230V50HZ)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With transformer

Height

170mm

Depth

76mm

Power consumption

1.4W

Width

45mm

Rated operation power at AC-3, 400 V

5.5kW

Overload release current setting

8 .. 12A

Number of auxiliary contacts as normally open contact

1

Rated operation current Ie

11.3A

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Number of indicator lights

0

Supporting protocol for ASI

Supporting protocol for CAN

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for LON

External reset possible

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP20

Supporting protocol for PROFIBUS

Suitable for emergency stop

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Number of command positions

0

Supporting protocol for SUCONET

Supporting protocol for INTERBUS

Rated control supply voltage Us at DC

0 .. 0V

Supporting protocol for other bus systems

Supporting protocol for Data-Highway

Rail mounting possible

Supporting protocol for TCP/IP

Release class

CLASS 10 A

Type of electrical connection of main circuit

Screw connection

With fuse

Rated operation power at AC-3, 230 V, 3-phase

3kW

Voltage type for actuating

AC

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

Supporting protocol for PROFIsafe

Rated power, 460 V, 60 Hz, 3-phase

0kW

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

With short-circuit release

Supporting protocol for DeviceNet Safety

Rated power, 575 V, 60 Hz, 3-phase

0kW

Supporting protocol for PROFINET CBA

Type of motor starter

Direct online starter (DOL)

Supporting protocol for PROFINET IO

Supporting protocol for SafetyBUS p

Rated conditional short-circuit current, type 2, 230 V

0A

Ambient temperature, upper operating limit

55°C

Temperature compensated overload protection

Rated operation current at AC-3, 400 V

12A

Rated conditional short-circuit current, type 2, 400 V

0A

Coordination class according to IEC 60947-4-3

Class 1

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Degree of protection (NEMA)

Other

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.