Technical specifications

Depth76mm
Rated operation power at AC-3, 400 V5.5kW
With transformerNo
Height170mm
Width45mm
Number of command positions0
Power consumption2.6W
Number of auxiliary contacts as normally open contact1
Suitable for emergency stopNo
Number of auxiliary contacts as normally closed contact0
Rated operation current Ie11.3A
Number of indicator lights0
Overload release current setting8 - 12A
Supporting protocol for LONNo
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Rail mounting possibleNo
Supporting protocol for ModbusNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for SUCONETNo
Degree of protection (IP)IP20
Rated control supply voltage Us at DC24 - 24V
Supporting protocol for other bus systemsNo
External reset possibleNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for SERCOSNo
Release classCLASS 10 A
With short-circuit releaseYes
Supporting protocol for DeviceNet SafetyNo
Type of electrical connection of main circuitScrew connection
Type of electrical connection for auxiliary- and control current circuitScrew connection
With fuseNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Rated operation power at AC-3, 230 V, 3-phase3kW
Rated power, 460 V, 60 Hz, 3-phase0kW
Type of motor starterDirect online starter (DOL)
Voltage type for actuatingDC
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Ambient temperature, upper operating limit55°C
Rated conditional short-circuit current, type 2, 400 V0A
Rated operation current at AC-3, 400 V12A
Rated conditional short-circuit current, type 2, 230 V0A
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Temperature compensated overload protectionYes
Coordination class according to IEC 60947-4-3Class 1
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DM-12-M12(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Depth

76mm

Rated operation power at AC-3, 400 V

5.5kW

With transformer

Height

170mm

Width

45mm

Number of command positions

0

Power consumption

2.6W

Number of auxiliary contacts as normally open contact

1

Suitable for emergency stop

Number of auxiliary contacts as normally closed contact

0

Rated operation current Ie

11.3A

Number of indicator lights

0

Overload release current setting

8 .. 12A

Supporting protocol for LON

Supporting protocol for TCP/IP

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rail mounting possible

Supporting protocol for Modbus

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for SUCONET

Degree of protection (IP)

IP20

Rated control supply voltage Us at DC

24 .. 24V

Supporting protocol for other bus systems

External reset possible

Supporting protocol for INTERBUS-Safety

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for SERCOS

Release class

CLASS 10 A

With short-circuit release

Supporting protocol for DeviceNet Safety

Type of electrical connection of main circuit

Screw connection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With fuse

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Rated operation power at AC-3, 230 V, 3-phase

3kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Type of motor starter

Direct online starter (DOL)

Voltage type for actuating

DC

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 2, 400 V

0A

Rated operation current at AC-3, 400 V

12A

Rated conditional short-circuit current, type 2, 230 V

0A

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Temperature compensated overload protection

Coordination class according to IEC 60947-4-3

Class 1

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.