Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Rated control supply voltage Us at AC 60HZ

0 - 0V

Rated control supply voltage Us at AC 50HZ

230 - 230V

Type of motor starter

Direct online starter (DOL)

With short-circuit release

Yes

Rated operation power at AC-3, 230 V, 3-phase

3kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation current Ie

11.3A

Voltage type for actuating

AC

Rated control supply voltage Us at DC

0 - 0V

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 400 V

5.5kW

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Overload release current setting

8 - 12A

Number of auxiliary contacts as normally closed contact

0

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 400 V

50000A

Number of auxiliary contacts as normally open contact

1

Power consumption

2.1W

Type of electrical connection of main circuit

Screw connection

Release class

CLASS 10 A

Number of command positions

0

Temperature compensated overload protection

Yes

Rated operation current at AC-3, 400 V

12A

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rail mounting possible

No

External reset possible

No

Suitable for emergency stop

No

Number of indicator lights

0

Ambient temperature, upper operating limit

55°C

Degree of protection (IP)

IP20

Coordination class according to IEC 60947-4-3

Class 2

With fuse

No

Supporting protocol for TCP/IP

No

Degree of protection (NEMA)

Other

Supporting protocol for PROFIBUS

No

Supporting protocol for CAN

No

With transformer

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for other bus systems

No

Supporting protocol for SafetyBUS p

No

Width

45mm

Height

197mm

Depth

97.5mm

Supporting protocol for Data-Highway

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for SERCOS

No

Supporting protocol for PROFINET IO

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for SUCONET

No

Supporting protocol for ASI

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for INTERBUS

No

Supporting protocol for LON

No

Supporting protocol for DeviceNet

No

Supporting protocol for Modbus

No


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

MSC-DM-12-M17(230V50HZ)

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Type of motor starter

Direct online starter (DOL)

With short-circuit release

Rated operation power at AC-3, 230 V, 3-phase

3kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation current Ie

11.3A

Voltage type for actuating

AC

Rated control supply voltage Us at DC

0 .. 0V

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 400 V

5.5kW

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Overload release current setting

8 .. 12A

Number of auxiliary contacts as normally closed contact

0

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 400 V

50000A

Number of auxiliary contacts as normally open contact

1

Power consumption

2.1W

Type of electrical connection of main circuit

Screw connection

Release class

CLASS 10 A

Number of command positions

0

Temperature compensated overload protection

Rated operation current at AC-3, 400 V

12A

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rail mounting possible

External reset possible

Suitable for emergency stop

Number of indicator lights

0

Ambient temperature, upper operating limit

55°C

Degree of protection (IP)

IP20

Coordination class according to IEC 60947-4-3

Class 2

With fuse

Supporting protocol for TCP/IP

Degree of protection (NEMA)

Other

Supporting protocol for PROFIBUS

Supporting protocol for CAN

With transformer

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for other bus systems

Supporting protocol for SafetyBUS p

Width

45mm

Height

197mm

Depth

97.5mm

Supporting protocol for Data-Highway

Supporting protocol for PROFINET CBA

Supporting protocol for SERCOS

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Supporting protocol for SUCONET

Supporting protocol for ASI

Supporting protocol for EtherNet/IP

Supporting protocol for INTERBUS

Supporting protocol for LON

Supporting protocol for DeviceNet

Supporting protocol for Modbus

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.