  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Supporting protocol for LONNo
Depth76mm
Suitable for emergency stopNo
With transformerNo
Rated operation current Ie0.8A
Width45mm
Power consumption1.4W
Height170mm
Number of indicator lights0
Rated operation power at AC-3, 400 V0.25kW
Number of command positions0
Number of auxiliary contacts as normally closed contact0
Overload release current setting0.63 - 1A
Number of auxiliary contacts as normally open contact1
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Supporting protocol for CANNo
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
External reset possibleNo
Supporting protocol for ModbusNo
Rated control supply voltage Us at AC 50HZ230 - 230V
Rail mounting possibleNo
Degree of protection (IP)IP20
Supporting protocol for DeviceNet SafetyNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for PROFINET CBANo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPNo
Rated control supply voltage Us at DC0 - 0V
Release classCLASS 10 A
With fuseNo
With short-circuit releaseYes
Type of motor starterDirect online starter (DOL)
Voltage type for actuatingAC
Rated operation current at AC-3, 400 V1A
Supporting protocol for PROFIsafeNo
Rated operation power at AC-3, 230 V, 3-phase0.12kW
Rated power, 460 V, 60 Hz, 3-phase0kW
Supporting protocol for SafetyBUS pNo
Rated power, 575 V, 60 Hz, 3-phase0kW
Supporting protocol for PROFINET IONo
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Degree of protection (NEMA)Other
Temperature compensated overload protectionYes
Coordination class according to IEC 60947-4-3Class 2
Ambient temperature, upper operating limit55°C
Rated conditional short-circuit current, type 2, 400 V50000A
Rated conditional short-circuit current, type 2, 230 V50000A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DM-1-M7(230V50HZ)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Supporting protocol for LON

Depth

76mm

Suitable for emergency stop

With transformer

Rated operation current Ie

0.8A

Width

45mm

Power consumption

1.4W

Height

170mm

Number of indicator lights

0

Rated operation power at AC-3, 400 V

0.25kW

Number of command positions

0

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

0.63 .. 1A

Number of auxiliary contacts as normally open contact

1

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Supporting protocol for CAN

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for other bus systems

External reset possible

Supporting protocol for Modbus

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Rail mounting possible

Degree of protection (IP)

IP20

Supporting protocol for DeviceNet Safety

Type of electrical connection of main circuit

Screw connection

Supporting protocol for Foundation Fieldbus

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for PROFINET CBA

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

Rated control supply voltage Us at DC

0 .. 0V

Release class

CLASS 10 A

With fuse

With short-circuit release

Type of motor starter

Direct online starter (DOL)

Voltage type for actuating

AC

Rated operation current at AC-3, 400 V

1A

Supporting protocol for PROFIsafe

Rated operation power at AC-3, 230 V, 3-phase

0.12kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Supporting protocol for SafetyBUS p

Rated power, 575 V, 60 Hz, 3-phase

0kW

Supporting protocol for PROFINET IO

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Degree of protection (NEMA)

Other

Temperature compensated overload protection

Coordination class according to IEC 60947-4-3

Class 2

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated conditional short-circuit current, type 2, 230 V

50000A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.