  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With transformerNo
Rated operation power at AC-3, 400 V0.25kW
Height170mm
Number of command positions0
Power consumption2.6W
Depth76mm
Width45mm
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact1
Supporting protocol for TCP/IPNo
Number of indicator lights0
Suitable for emergency stopNo
Supporting protocol for LONNo
Overload release current setting0.63 - 1A
Supporting protocol for CANNo
Supporting protocol for ASINo
Rated operation current Ie0.8A
Supporting protocol for PROFIBUSNo
Supporting protocol for other bus systemsNo
Supporting protocol for Data-HighwayNo
External reset possibleNo
Supporting protocol for SUCONETNo
Supporting protocol for ModbusNo
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUSNo
Degree of protection (IP)IP20
Supporting protocol for SERCOSNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for INTERBUS-SafetyNo
Rated control supply voltage Us at DC24 - 24V
Rated control supply voltage Us at AC 50HZ0 - 0V
Release classCLASS 10 A
Rail mounting possibleNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
With short-circuit releaseYes
Supporting protocol for PROFINET IONo
Type of electrical connection of main circuitScrew connection
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET CBANo
With fuseNo
Supporting protocol for SafetyBUS pNo
Type of motor starterDirect online starter (DOL)
Supporting protocol for PROFIsafeNo
Rated power, 575 V, 60 Hz, 3-phase0kW
Voltage type for actuatingDC
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated operation power at AC-3, 230 V, 3-phase0.12kW
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 400 V50000A
Rated conditional short-circuit current, type 2, 230 V50000A
Rated operation current at AC-3, 400 V1A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Degree of protection (NEMA)Other
Temperature compensated overload protectionYes
Ambient temperature, upper operating limit55°C
Coordination class according to IEC 60947-4-3Class 2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DM-1-M7(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With transformer

Rated operation power at AC-3, 400 V

0.25kW

Height

170mm

Number of command positions

0

Power consumption

2.6W

Depth

76mm

Width

45mm

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

1

Supporting protocol for TCP/IP

Number of indicator lights

0

Suitable for emergency stop

Supporting protocol for LON

Overload release current setting

0.63 .. 1A

Supporting protocol for CAN

Supporting protocol for ASI

Rated operation current Ie

0.8A

Supporting protocol for PROFIBUS

Supporting protocol for other bus systems

Supporting protocol for Data-Highway

External reset possible

Supporting protocol for SUCONET

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS

Degree of protection (IP)

IP20

Supporting protocol for SERCOS

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for INTERBUS-Safety

Rated control supply voltage Us at DC

24 .. 24V

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Release class

CLASS 10 A

Rail mounting possible

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

With short-circuit release

Supporting protocol for PROFINET IO

Type of electrical connection of main circuit

Screw connection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET CBA

With fuse

Supporting protocol for SafetyBUS p

Type of motor starter

Direct online starter (DOL)

Supporting protocol for PROFIsafe

Rated power, 575 V, 60 Hz, 3-phase

0kW

Voltage type for actuating

DC

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 230 V, 3-phase

0.12kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated operation current at AC-3, 400 V

1A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Degree of protection (NEMA)

Other

Temperature compensated overload protection

Ambient temperature, upper operating limit

55°C

Coordination class according to IEC 60947-4-3

Class 2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.