Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-DM-1-M7(24VDC)

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With transformer
Rated operation power at AC-3, 400 V
0.25kW
Height
170mm
Number of command positions
0
Power consumption
2.6W
Depth
76mm
Width
45mm
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
1
Supporting protocol for TCP/IP
Number of indicator lights
0
Suitable for emergency stop
Supporting protocol for LON
Overload release current setting
0.63 .. 1A
Supporting protocol for CAN
Supporting protocol for ASI
Rated operation current Ie
0.8A
Supporting protocol for PROFIBUS
Supporting protocol for other bus systems
Supporting protocol for Data-Highway
External reset possible
Supporting protocol for SUCONET
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for INTERBUS
Degree of protection (IP)
IP20
Supporting protocol for SERCOS
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Supporting protocol for INTERBUS-Safety
Rated control supply voltage Us at DC
24 .. 24V
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Release class
CLASS 10 A
Rail mounting possible
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
With short-circuit release
Supporting protocol for PROFINET IO
Type of electrical connection of main circuit
Screw connection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFINET CBA
With fuse
Supporting protocol for SafetyBUS p
Type of motor starter
Direct online starter (DOL)
Supporting protocol for PROFIsafe
Rated power, 575 V, 60 Hz, 3-phase
0kW
Voltage type for actuating
DC
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 230 V, 3-phase
0.12kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated operation current at AC-3, 400 V
1A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Degree of protection (NEMA)
Other
Temperature compensated overload protection
Ambient temperature, upper operating limit
55°C
Coordination class according to IEC 60947-4-3
Class 2