Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width45mm
Number of command positions0
Number of indicator lights0
Number of auxiliary contacts as normally closed contact0
Rated operation current Ie1.9A
Depth76mm
Number of auxiliary contacts as normally open contact1
Suitable for emergency stopNo
Power consumption2.6W
Height170mm
With transformerNo
Rated operation power at AC-3, 400 V0.75kW
Supporting protocol for ModbusNo
Overload release current setting1.6 - 2.5A
Supporting protocol for LONNo
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Supporting protocol for CANNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for Data-HighwayNo
Rail mounting possibleNo
External reset possibleNo
Supporting protocol for other bus systemsNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Degree of protection (IP)IP20
Supporting protocol for SERCOSNo
Rated control supply voltage Us at DC24 - 24V
Supporting protocol for INTERBUS-SafetyNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
With short-circuit releaseYes
With fuseNo
Type of electrical connection of main circuitScrew connection
Release classCLASS 10 A
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFIsafeNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Voltage type for actuatingDC
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated operation current at AC-3, 400 V2.5A
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated operation power at AC-3, 230 V, 3-phase0.37kW
Type of motor starterDirect online starter (DOL)
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Ambient temperature, upper operating limit55°C
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 2, 400 V50000A
Rated conditional short-circuit current, type 2, 230 V50000A
Coordination class according to IEC 60947-4-3Class 2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DM-2,5-M7(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width

45mm

Number of command positions

0

Number of indicator lights

0

Number of auxiliary contacts as normally closed contact

0

Rated operation current Ie

1.9A

Depth

76mm

Number of auxiliary contacts as normally open contact

1

Suitable for emergency stop

Power consumption

2.6W

Height

170mm

With transformer

Rated operation power at AC-3, 400 V

0.75kW

Supporting protocol for Modbus

Overload release current setting

1.6 .. 2.5A

Supporting protocol for LON

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Supporting protocol for ASI

Supporting protocol for CAN

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Supporting protocol for Data-Highway

Rail mounting possible

External reset possible

Supporting protocol for other bus systems

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Degree of protection (IP)

IP20

Supporting protocol for SERCOS

Rated control supply voltage Us at DC

24 .. 24V

Supporting protocol for INTERBUS-Safety

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With short-circuit release

With fuse

Type of electrical connection of main circuit

Screw connection

Release class

CLASS 10 A

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for PROFIsafe

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Voltage type for actuating

DC

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

2.5A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Type of motor starter

Direct online starter (DOL)

Temperature compensated overload protection

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated conditional short-circuit current, type 2, 230 V

50000A

Coordination class according to IEC 60947-4-3

Class 2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.