- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated control supply voltage Us at DC
24 - 24V
Rated control supply voltage Us at AC 50HZ
0 - 0V
Type of motor starter
Direct online starter (DOL)
Rated operation current at AC-3, 400 V
2.5A
With short-circuit release
Yes
Rated operation power at AC-3, 400 V
0.75kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Overload release current setting
1.6 - 2.5A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated operation current Ie
1.9A
Rated control supply voltage Us at AC 60HZ
0 - 0V
Voltage type for actuating
DC
Ambient temperature, upper operating limit
55°C
Release class
CLASS 10 A
Power consumption
2.6W
Number of auxiliary contacts as normally open contact
1
Type of electrical connection of main circuit
Screw connection
Coordination class according to IEC 60947-4-3
Class 2
Rated conditional short-circuit current, type 2, 400 V
50000A
Suitable for emergency stop
No
Rated conditional short-circuit current, type 2, 230 V
50000A
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Temperature compensated overload protection
Yes
Number of command positions
0
External reset possible
No
Degree of protection (NEMA)
Other
Degree of protection (IP)
IP20
Number of indicator lights
0
Supporting protocol for TCP/IP
No
Supporting protocol for CAN
No
Supporting protocol for PROFIBUS
No
Supporting protocol for INTERBUS
No
With transformer
No
Rail mounting possible
No
Supporting protocol for AS-Interface Safety at Work
No
With fuse
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Height
170mm
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Depth
76mm
Width
45mm
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for Modbus
No
Supporting protocol for SUCONET
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for LON
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for ASI
No
From same serie
MSC-DM-2,5-M7(24VDC)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated control supply voltage Us at DC
24 .. 24V
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Type of motor starter
Direct online starter (DOL)
Rated operation current at AC-3, 400 V
2.5A
With short-circuit release
Rated operation power at AC-3, 400 V
0.75kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Overload release current setting
1.6 .. 2.5A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated operation current Ie
1.9A
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Voltage type for actuating
DC
Ambient temperature, upper operating limit
55°C
Release class
CLASS 10 A
Power consumption
2.6W
Number of auxiliary contacts as normally open contact
1
Type of electrical connection of main circuit
Screw connection
Coordination class according to IEC 60947-4-3
Class 2
Rated conditional short-circuit current, type 2, 400 V
50000A
Suitable for emergency stop
Rated conditional short-circuit current, type 2, 230 V
50000A
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Temperature compensated overload protection
Number of command positions
0
External reset possible
Degree of protection (NEMA)
Other
Degree of protection (IP)
IP20
Number of indicator lights
0
Supporting protocol for TCP/IP
Supporting protocol for CAN
Supporting protocol for PROFIBUS
Supporting protocol for INTERBUS
With transformer
Rail mounting possible
Supporting protocol for AS-Interface Safety at Work
With fuse
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Height
170mm
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Depth
76mm
Width
45mm
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
Supporting protocol for Modbus
Supporting protocol for SUCONET
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for SERCOS
Supporting protocol for LON
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for ASI