Technical specifications

Type of motor starterDirect online starter (DOL)
Rated operation power at AC-3, 400 V1.5kW
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated operation current Ie3.6A
Rated control supply voltage Us at AC 50HZ0 - 0V
Rated power, 575 V, 60 Hz, 3-phase0kW
Voltage type for actuatingDC
Rated control supply voltage Us at DC24 - 24V
Rated operation power at AC-3, 230 V, 3-phase0.75kW
With short-circuit releaseYes
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated operation current at AC-3, 400 V4A
Power consumption2.6W
Rated conditional short-circuit current, type 2, 400 V50000A
Rated power, 460 V, 60 Hz, 3-phase0kW
Temperature compensated overload protectionYes
Ambient temperature, upper operating limit55°C
Type of electrical connection of main circuitScrew connection
Release classCLASS 10 A
Rated conditional short-circuit current, type 2, 230 V50000A
Number of command positions0
With transformerNo
Rail mounting possibleNo
Overload release current setting2.5 - 4A
External reset possibleNo
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact1
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Suitable for emergency stopNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Number of indicator lights0
Coordination class according to IEC 60947-4-3Class 2
Degree of protection (IP)IP20
Degree of protection (NEMA)Other
Supporting protocol for Data-HighwayNo
Supporting protocol for TCP/IPNo
Supporting protocol for ModbusNo
Supporting protocol for SERCOSNo
Supporting protocol for SUCONETNo
Supporting protocol for PROFINET IONo
Supporting protocol for LONNo
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
With fuseNo
Supporting protocol for CANNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for DeviceNetNo
Supporting protocol for PROFIBUSNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Height170mm
Depth76mm
Width45mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DM-4-M7(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Rated operation power at AC-3, 400 V

1.5kW

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated operation current Ie

3.6A

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rated power, 575 V, 60 Hz, 3-phase

0kW

Voltage type for actuating

DC

Rated control supply voltage Us at DC

24 .. 24V

Rated operation power at AC-3, 230 V, 3-phase

0.75kW

With short-circuit release

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated operation current at AC-3, 400 V

4A

Power consumption

2.6W

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Temperature compensated overload protection

Ambient temperature, upper operating limit

55°C

Type of electrical connection of main circuit

Screw connection

Release class

CLASS 10 A

Rated conditional short-circuit current, type 2, 230 V

50000A

Number of command positions

0

With transformer

Rail mounting possible

Overload release current setting

2.5 .. 4A

External reset possible

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

1

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Suitable for emergency stop

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Number of indicator lights

0

Coordination class according to IEC 60947-4-3

Class 2

Degree of protection (IP)

IP20

Degree of protection (NEMA)

Other

Supporting protocol for Data-Highway

Supporting protocol for TCP/IP

Supporting protocol for Modbus

Supporting protocol for SERCOS

Supporting protocol for SUCONET

Supporting protocol for PROFINET IO

Supporting protocol for LON

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

With fuse

Supporting protocol for CAN

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Height

170mm

Depth

76mm

Width

45mm