Aleta.hr
Main Product Image

MSC-DM-4-M7(24VDC)

Code: 1957905

ManufacturerRAZNO
Catalog number188261
Type
EAN code4015081861460

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Rated operation power at AC-3, 400 V

1.5kW

Rated control supply voltage Us at AC 60HZ

0 - 0V

Rated operation current Ie

3.6A

Rated control supply voltage Us at AC 50HZ

0 - 0V

Rated power, 575 V, 60 Hz, 3-phase

0kW

Voltage type for actuating

DC

Rated control supply voltage Us at DC

24 - 24V

Rated operation power at AC-3, 230 V, 3-phase

0.75kW

With short-circuit release

Yes

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated operation current at AC-3, 400 V

4A

Power consumption

2.6W

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Temperature compensated overload protection

Yes

Ambient temperature, upper operating limit

55°C

Type of electrical connection of main circuit

Screw connection

Release class

CLASS 10 A

Rated conditional short-circuit current, type 2, 230 V

50000A

Number of command positions

0

With transformer

No

Rail mounting possible

No

Overload release current setting

2.5 - 4A

External reset possible

No

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

1

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Suitable for emergency stop

No

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Number of indicator lights

0

Coordination class according to IEC 60947-4-3

Class 2

Degree of protection (IP)

IP20

Degree of protection (NEMA)

Other

Supporting protocol for Data-Highway

No

Supporting protocol for TCP/IP

No

Supporting protocol for Modbus

No

Supporting protocol for SERCOS

No

Supporting protocol for SUCONET

No

Supporting protocol for PROFINET IO

No

Supporting protocol for LON

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for Foundation Fieldbus

No

With fuse

No

Supporting protocol for CAN

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for DeviceNet

No

Supporting protocol for PROFIBUS

No

Supporting protocol for INTERBUS

No

Supporting protocol for ASI

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for SafetyBUS p

No

Supporting protocol for other bus systems

No

Height

170mm

Depth

76mm

Width

45mm


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

MSC-DM-4-M7(24VDC)

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Rated operation power at AC-3, 400 V

1.5kW

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated operation current Ie

3.6A

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rated power, 575 V, 60 Hz, 3-phase

0kW

Voltage type for actuating

DC

Rated control supply voltage Us at DC

24 .. 24V

Rated operation power at AC-3, 230 V, 3-phase

0.75kW

With short-circuit release

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated operation current at AC-3, 400 V

4A

Power consumption

2.6W

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Temperature compensated overload protection

Ambient temperature, upper operating limit

55°C

Type of electrical connection of main circuit

Screw connection

Release class

CLASS 10 A

Rated conditional short-circuit current, type 2, 230 V

50000A

Number of command positions

0

With transformer

Rail mounting possible

Overload release current setting

2.5 .. 4A

External reset possible

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

1

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Suitable for emergency stop

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Number of indicator lights

0

Coordination class according to IEC 60947-4-3

Class 2

Degree of protection (IP)

IP20

Degree of protection (NEMA)

Other

Supporting protocol for Data-Highway

Supporting protocol for TCP/IP

Supporting protocol for Modbus

Supporting protocol for SERCOS

Supporting protocol for SUCONET

Supporting protocol for PROFINET IO

Supporting protocol for LON

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

With fuse

Supporting protocol for CAN

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Height

170mm

Depth

76mm

Width

45mm

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.