Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Number of command positions0
Depth76mm
With transformerNo
Height170mm
Power consumption2.6W
Number of auxiliary contacts as normally closed contact0
Rated operation current Ie3.6A
Width45mm
Rated operation power at AC-3, 400 V1.5kW
Number of auxiliary contacts as normally open contact1
Number of indicator lights0
Overload release current setting2.5 - 4A
Suitable for emergency stopNo
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for SUCONETNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for TCP/IPNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for other bus systemsNo
Supporting protocol for AS-Interface Safety at WorkNo
Rail mounting possibleNo
External reset possibleNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Type of electrical connection for auxiliary- and control current circuitScrew connection
Rated control supply voltage Us at DC24 - 24V
With fuseNo
With short-circuit releaseYes
Degree of protection (IP)IP20
Supporting protocol for LONNo
Release classCLASS 10 A
Type of electrical connection of main circuitScrew connection
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Temperature compensated overload protectionYes
Type of motor starterDirect online starter (DOL)
Rated conditional short-circuit current, type 2, 400 V50000A
Ambient temperature, upper operating limit55°C
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated operation current at AC-3, 400 V4A
Rated operation power at AC-3, 230 V, 3-phase0.75kW
Rated power, 460 V, 60 Hz, 3-phase0kW
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Voltage type for actuatingDC
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPNo
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Supporting protocol for DeviceNet SafetyNo
Coordination class according to IEC 60947-4-3Class 2
Supporting protocol for SafetyBUS pNo
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 2, 230 V50000A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DM-4-M7(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Number of command positions

0

Depth

76mm

With transformer

Height

170mm

Power consumption

2.6W

Number of auxiliary contacts as normally closed contact

0

Rated operation current Ie

3.6A

Width

45mm

Rated operation power at AC-3, 400 V

1.5kW

Number of auxiliary contacts as normally open contact

1

Number of indicator lights

0

Overload release current setting

2.5 .. 4A

Suitable for emergency stop

Supporting protocol for ASI

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for SUCONET

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for TCP/IP

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Supporting protocol for other bus systems

Supporting protocol for AS-Interface Safety at Work

Rail mounting possible

External reset possible

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rated control supply voltage Us at DC

24 .. 24V

With fuse

With short-circuit release

Degree of protection (IP)

IP20

Supporting protocol for LON

Release class

CLASS 10 A

Type of electrical connection of main circuit

Screw connection

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Temperature compensated overload protection

Type of motor starter

Direct online starter (DOL)

Rated conditional short-circuit current, type 2, 400 V

50000A

Ambient temperature, upper operating limit

55°C

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

4A

Rated operation power at AC-3, 230 V, 3-phase

0.75kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Voltage type for actuating

DC

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Supporting protocol for DeviceNet Safety

Coordination class according to IEC 60947-4-3

Class 2

Supporting protocol for SafetyBUS p

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 2, 230 V

50000A